background image

 

   

Instructions pH FUN V1

 

 

 

Page 10 of 28 

Maintaining the pH FUN 

 

 

ATTENTION:

    

Disconnect all power connections before beginning maintenance work! 

3.1 

Maintenance plan 

 

Monthly maintenance: 

 

Visually inspect all dosing lines and hoses for leakage  

 

Check the filter sieve and clean it if necessary. Repeat this step more often for strong contamination. 

 

Check the pH value using a test kit (commercially available), adjust the settings if necessary 

 

Quarterly maintenance: 

 

Visually inspect all dosing lines and hoses for leakage's 

 

Check the filter sieve and clean it if necessary 

 

Check the pH value using a test kit (commercially available), adjust the settings if necessary 

 

Calibrate the pH electrode with supplied buffer solution (see Chapter 6 Performing the pH7 calib) 

 

Annual maintenance: 

 

Visually inspect all dosing lines and hoses for leakage's 

 

Check the filter sieve and clean it if necessary 

 

Check the pH value using a test kit (commercially available), adjust the settings if necessary 

 

Replace and calibrate the pH electrode with supplied buffer solution (see Chapter 6 Performing the pH7 calib) 

 

Replace the hoses of the dosing pumps 
 

3.1.1  Checking the hoses 

Check all hoses for damage (e.g. kinks, tears or leakage's), contamination (e.g. leaves, hair, dust or earth) and 
deposits (e.g. limescale). 
If there is any doubt, always replace the affected lines. This is the only way to ensure a proper operation.  

3.1.2  Cleaning the filter 

Close the valve of the measurement water extractor and then the valve of the measurement water return. No further 
water is now transported through the measurement cell and filter and the float of the flow switch sinks downwards. Now 
unscrew the transparent cover of the filter. Use a container to catch any water that runs out.  
Remove the filter sieve and clean it carefully. Use clear water to rinse it.  
Now reinsert the filter securely in its seat and screw on the cover again. Make sure the connection is tight.  

3.1.3  Dosing pump hoses 

The hose of the dosing pump must be replaced annually or earlier if worn. Use the original replacement hose only. You 
can obtain this at your swimming pool dealer under BAYROL Art. no.: 171 219  Replacement hose set 0.9 l/h 
(identifiable by the white hose nozzles). 

 

Like the pH electrode, the hose of the dosing pump is also a wear part and is exempted from the guarantee/warranty. 

Содержание pH FUN

Страница 1: ...Instructions pH FUN V1 Page 1 of 28 Instruction manual pH FUN...

Страница 2: ...ng field of the pH FUN 13 4 1 1 Button functions in the normal view 14 4 1 2 Performing a parameter setting 14 4 2 The pH FUN menu 14 4 3 Setting options of the pH FUN 16 4 3 1 Menu navigation 16 4 3...

Страница 3: ...d operated by qualified expert personnel General danger warning Changing the system settings default values can be dangerous to persons under certain circumstances Therefore changes must only be made...

Страница 4: ...ok after the disinfection The use of BAYROL algaecide and flocculant products is additionally recommended The product program is perfectly matched to guarantee a perfect water quality with very little...

Страница 5: ...ck that the float in the measurement chamber can float freely Adjust the water flow through the cell so that the float just barely lies against the upper end in its guide bore Ensure that connections...

Страница 6: ...lowed The equipment should be installed by a licensed electrician The supply voltage for the device may not exceed 240V 50 Hz The allowable operating temperature range is from 0 to 50 O C and the allo...

Страница 7: ...to the measurement cell it must be fed directly into the circulating line You will require the following accessories available at your BAYROL dealer 100 509 PE hose length depending on the installatio...

Страница 8: ...Measurement water intake 6 Heat exchanger 7 Sand filter 8 Measurement water extractor 9 Circulating pump 10 Container for pH Minus liquid 11 pH Minus suction line 1 pH FUN Chlorine 2 Swimming pool 3 M...

Страница 9: ...available Use Europe for all countries not listed Confirm with Pool volume Enter the volume of the swimming pool in m cubic meter using the arrow keys and confirm with The input of the pool volume se...

Страница 10: ...Performing the pH7 calib Replace the hoses of the dosing pumps 3 1 1 Checking the hoses Check all hoses for damage e g kinks tears or leakage s contamination e g leaves hair dust or earth and deposits...

Страница 11: ...the air from the dosing hose To do so connect pH FUN with the mains and start a manual dosing The purging is complete when you can no longer detect air bubbles on either the suction side canister pum...

Страница 12: ...ecautionary measures need to be taken In particular it is very important that the entire system is protected against freezing temperatures and humidity Dosing system Rinse the pump with fresh lukewarm...

Страница 13: ...ming a manual dosing The length of time or dose amount of the manual dosing can be set in the menu xx min Remaining time in minutes of a running manual dosing The remaining time is counted down during...

Страница 14: ...provides an overview of all important current measurement and control parameters You can also set the operating mode in the normal view of the pH FUN Normally the pH FUN automatically ensures the opti...

Страница 15: ...0 min Language German Language German Default Europe Initial operation Menu Normal operation 2 sec 2 sec If an alarm occurs a jump occurs automatically to the alarm display OK confirms all current pen...

Страница 16: ...des Auto Man Man and Off are described in the table in section 4 1 Display and operating field of the pH FUN The execution of a manual dosing is additionally described in more detail in Chapter5 Perfo...

Страница 17: ...The standard setting should only then be modified when the pH value of the pool water either does not reach the desired setpoint or overshoots the desired setpoint see also Chapter 9 3 The pH value i...

Страница 18: ...does not activate as expected the time interval can be adapted accordingly see Chapter 9 1 The pH FUN reports an alarm Danger warning By setting the time interval to 0 minutes the dosing alarm is com...

Страница 19: ...or Off You can abort a running manual dosing at any time by resetting the operating mode to Auto or Off 5 1 Calculating the manual dosing The following approximation formula can be used to calculate...

Страница 20: ...the pH FUN device beforehand so that the electrode cable does not get twisted when unscrewing the electrode Handle the electrode by its plastic shaft only 5 Rinse the electrode in clean water and the...

Страница 21: ...to play when calculating the dosing rate Parameter Explanation Current pH value in the pool water Desired pH setpoint The stronger the currently measured pH value of the pool water deviates from the s...

Страница 22: ...m During a dosing alarm Only when the reason for the blocking is no longer present will the pH FUN again enable the dosing When dosing is blocked the pH FUN always shows a dosing rate of 0 in the norm...

Страница 23: ...el of the canister in this case is no longer sufficient for an additional dosing the dosing is blocked Replace the empty canister The pH FUN subsequently resumes with the dosing Dosing alarm If the cu...

Страница 24: ...f the pool water is too high An overdosing of pH Plus may possibly have occurred Reduce the value of the Min dos rate parameter see 4 3 3 Setting options in the menu in 3 steps to reduce the dosing ra...

Страница 25: ...l overshoots the set setpoint An overdosing of pH Minus has occurred The dosing rate of the pH FUN is too high for the pool particularly in the area of the setpoint Reduce the value of the Min dos rat...

Страница 26: ...correct measured values The pH7 buffer solution may possibly be contaminated and shows an incorrect pH value The correct sequence for the pH7 calibration may not have been adhered to precisely The pH...

Страница 27: ...Level input signal 11 pH input signal 11 12 pH input to the connector of the pH electrode 12 pH input GND 10 2 Replacing the fuses There are 2 fuses on the circuit board No Fuse of Fuse F1 Power supp...

Страница 28: ...ller and carefully remove the housing Be careful not to damage the circular seal inserted The fuses are located in a special holder and can be easily replaced The fuse holder is opened using a flat sc...

Отзывы: