background image

 

 

4.2 Installing the battery/Charging 

 

 

1

 

 

Slide  the  battery  towards  the  back  of  the 

filtration unit.

 

 

 

2

 

 

Make  sure  that  the  battery  is  locked  in 

position.

 

 

 

3

 

     

 

                       

The battery can be charged on the filtration unit or separately.

 

 

The battery is partially charged when delivered. It must be 

charged to 100% (4 bars) before first use. 

                 

  It is recommended to charge the battery to 100% before each use. 

 

The charger must not be used for anything other than it was designed for.    Do not 

charge the battery in a potentially explosive area. The charger must 

only be used indoors. 

The charger regulates the charge automatically, once the battery is fully     

                      charged, the charger will maintain the charge at 100%. 

 
                      The charge time is 3 to 4 hours. 

 

The  battery  will  discharge  after  long  storage  periods.  Always 

charge the battery if the device has been stored for more than 15 

days. When the battery is new or has been stored for more than 

3 months, charge it and discharge it at least twice in a row to reach 

the nominal/rated charge capacity. 

 

Содержание PeRSo 3.0

Страница 1: ...PeRSo 3 0 User Manual Powered Air Purifying Respirator Please read these instructions carefully before using the equipment Incorrect use can result in risk to life and health...

Страница 2: ...athing protection device It protects against particulate contamination All components used in the Respiratory System must be manufacturer approved parts and must be used in accordance with the instruc...

Страница 3: ...evice is in the power off state a rapid build up of carbon dioxide and depletion of oxygen within the hood may occur The filters shall only be fitted to the blower unit and not directly to the helmet...

Страница 4: ...parts must be replaced before use FIGURE 1 The package must include 1 The air fed hood 2 The respiratory protection system blower unit filter waist belt 3 Lithium ion battery 4 The tube and end fittin...

Страница 5: ...filter cover is released 3 Remove the used filter by lifting it out from the filter cover 4 5 Remove the pre filter The pre filter and filter expected lifetime is 12 months When under intensive use c...

Страница 6: ...e used for anything other than it was designed for Do not charge the battery in a potentially explosive area The charger must only be used indoors The charger regulates the charge automatically once t...

Страница 7: ...sconnect the charger from the mains do not keep the charger plugged in to the mains if it s not in use 4 3 Installing the respirator system on the belt 1 Remove the belt s release buckle 2 Remove the...

Страница 8: ...ist it clockwise to lock its position 2 Connect the other end of the tube to the headgear in the same way 1 Check that the respirator tube is firmly connected If the tube is broken replace it All comp...

Страница 9: ...flow is sufficient if the marble reaches the minimum flow level O 1 The airflow must be tested before using 2 If the marble can t reach the minimum flow level don t use the system Change the filter o...

Страница 10: ...show the PERSO 3 0 operating status FIGURE 3 FIGURE 3 Part 1 shows the current air flow rate Part 2 shows the level of the airflow Part 3 shows the filter condition Part 4 shows the battery Part 5 sh...

Страница 11: ...is at level 3 230L min Press the ON button once again the air flow reverts to level 1 170L min 1 To turn off the blower unit long press the OFF button for more than 3 seconds 2 The Respirator system...

Страница 12: ...P3 04 03T 001 Pre filter 4 P3 04 04T 001 Filter 5 P3 04 05T 001 Blower Unit 6 P3 05 01T 001 Waist Belt 7 P3 05 02T 001 Shoulder Harness 8 P3 03 01T 001 Standard Battery P3 03 01T 002 Heavy Duty Batte...

Страница 13: ......

Страница 14: ...external surfaces Don t use water The filter should be replaced together with the pre filter 8 2 Storage The Respirator system must be stored in a dry clean area in the temperature range of 10 to 55...

Страница 15: ...d Tube blocked Remove obstruction change the filter Clean tube blinks alarm sounds Battery high temperature Stop working and rest No air flow no alarm 1 No power 2 Battery contact damaged Charge the b...

Страница 16: ...ture 14 to 131 10 55 Battery Type Standard Battery Rechargeable Li ION 4400mAh Optional Heavy Duty Battery Rechargeable Li ION 6800mAh Expected Battery Operation Time Standard Battery Level 1 8h Level...

Страница 17: ...lter type P Particle filter R Reusable type of particle filters and SL reflects the filter has been tested against particles of liquid and solid matter Warning sound indication This PERSO 3 0 PAPR has...

Страница 18: ...om the date of purchase The company undertakes to exchange or repair without charge any part found to be defective within this period alternatively and at its discretion The Company may replace This g...