The manufacturer is not responsible for injury due to the following 

incorrect use or incorrect choice of equipment. 

 

Warning: 

This respirator device should be used by trained personal and qualified personnel only.   

Before using the devices ensure you have understood that at very high work rates the 

pressure in the device may become negative at peak inhalation flow. 

Before and during using the device, attention shall be drawn to possible incorrect use 

and,  where  appropriate,  the  possibility  of  looped  hoses  and/or  cables  becoming 

entangled. 

Before or during use of the device, if the device is in the power-off state no respiratory 

protection is to be expected. 

Please leave the work place and remove the headgear, when the device is in the power-

off state a rapid build-up of carbon dioxide and depletion of oxygen within the hood may 

occur. 

The filters shall only be fitted to the blower unit and not directly to the helmet/hood. 

The user should not confuse the markings on a filter relating to any standard other than 

EN 12941 with the classification of this device when used with this filter. 

 

DO NOT use PERSO 3.0 with the blower unit switched off. 

DO  NOT  use  PERSO  3.0  in  an  atmosphere  that  is  immediately  hazardous  to  user 

hygiene or health and/or has oxygen content of less than 19.5% or contains unknown 

substances. 

DO NOT use PERSO 3.0 in an explosive atmosphere. 

DO NOT use PERSO 3.0 in confined spaces or areas of poor ventilation 

DO NOT use PERSO 3.0 in high winds. 

DO NOT alter or modify in any way. 

DO NOT touch any of the moving parts. 

DO NOT allow water or other liquids to enter the impeller chamber, the filter or battery 

compartment. 

 

Содержание PeRSo 3.0

Страница 1: ...PeRSo 3 0 User Manual Powered Air Purifying Respirator Please read these instructions carefully before using the equipment Incorrect use can result in risk to life and health...

Страница 2: ...athing protection device It protects against particulate contamination All components used in the Respiratory System must be manufacturer approved parts and must be used in accordance with the instruc...

Страница 3: ...evice is in the power off state a rapid build up of carbon dioxide and depletion of oxygen within the hood may occur The filters shall only be fitted to the blower unit and not directly to the helmet...

Страница 4: ...parts must be replaced before use FIGURE 1 The package must include 1 The air fed hood 2 The respiratory protection system blower unit filter waist belt 3 Lithium ion battery 4 The tube and end fittin...

Страница 5: ...filter cover is released 3 Remove the used filter by lifting it out from the filter cover 4 5 Remove the pre filter The pre filter and filter expected lifetime is 12 months When under intensive use c...

Страница 6: ...e used for anything other than it was designed for Do not charge the battery in a potentially explosive area The charger must only be used indoors The charger regulates the charge automatically once t...

Страница 7: ...sconnect the charger from the mains do not keep the charger plugged in to the mains if it s not in use 4 3 Installing the respirator system on the belt 1 Remove the belt s release buckle 2 Remove the...

Страница 8: ...ist it clockwise to lock its position 2 Connect the other end of the tube to the headgear in the same way 1 Check that the respirator tube is firmly connected If the tube is broken replace it All comp...

Страница 9: ...flow is sufficient if the marble reaches the minimum flow level O 1 The airflow must be tested before using 2 If the marble can t reach the minimum flow level don t use the system Change the filter o...

Страница 10: ...show the PERSO 3 0 operating status FIGURE 3 FIGURE 3 Part 1 shows the current air flow rate Part 2 shows the level of the airflow Part 3 shows the filter condition Part 4 shows the battery Part 5 sh...

Страница 11: ...is at level 3 230L min Press the ON button once again the air flow reverts to level 1 170L min 1 To turn off the blower unit long press the OFF button for more than 3 seconds 2 The Respirator system...

Страница 12: ...P3 04 03T 001 Pre filter 4 P3 04 04T 001 Filter 5 P3 04 05T 001 Blower Unit 6 P3 05 01T 001 Waist Belt 7 P3 05 02T 001 Shoulder Harness 8 P3 03 01T 001 Standard Battery P3 03 01T 002 Heavy Duty Batte...

Страница 13: ......

Страница 14: ...external surfaces Don t use water The filter should be replaced together with the pre filter 8 2 Storage The Respirator system must be stored in a dry clean area in the temperature range of 10 to 55...

Страница 15: ...d Tube blocked Remove obstruction change the filter Clean tube blinks alarm sounds Battery high temperature Stop working and rest No air flow no alarm 1 No power 2 Battery contact damaged Charge the b...

Страница 16: ...ture 14 to 131 10 55 Battery Type Standard Battery Rechargeable Li ION 4400mAh Optional Heavy Duty Battery Rechargeable Li ION 6800mAh Expected Battery Operation Time Standard Battery Level 1 8h Level...

Страница 17: ...lter type P Particle filter R Reusable type of particle filters and SL reflects the filter has been tested against particles of liquid and solid matter Warning sound indication This PERSO 3 0 PAPR has...

Страница 18: ...om the date of purchase The company undertakes to exchange or repair without charge any part found to be defective within this period alternatively and at its discretion The Company may replace This g...

Отзывы: