Nautica 250 Installation Guide
301789-A Rev.00
3
Site Preparation
You should install the Nautica 250 on a flat surface, in a clean,
dry location with no extreme temperatures. Make sure that all of
the required services (power, LAN access, ISDN, and any
telephones, facsimiles, and modems) are available and working
correctly.
Make sure that there is sufficient space on all sides of the Nautica
250 to ensure that it does not exceed the maximum temperature
(
Table 1
).
Table 1
lists the operating requirements for correct installation of
the Nautica 250.
Table 1.
Operating Requirements
Parameter
Specification
Power supply: Europe
220 to 240 VAC, 50 Hz (nominal)
Power supply: North America
110 VAC, 60 Hz
Power supply current
41 mA @ 240 VAC
90 mA @ 110 VAC
Power consumption
10 W (nominal)
Operating temperature
10
o
to 40
o
C (50
o
to 104
o
F)
Humidity
5% to 95% (nonconducting)
LAN cable (maximum length)
100 m Cat 3 or 5
Telephone ports (two)
You can connect a facsimile,
telephone or modem to these
ports.
Note:
Before you begin the installation, make sure you have
everything you need. See
Checklist
on
page 2
.