34
2.
Remove the cascade cable from the Cascade A In
connector at unit 5.
3.
Remove the units (units 3 and 4) and install
replacement units as required.
4.
Renumber the order of the units for the new stack
configuration (if desired).
You can renumber the unit numbers as described in
“Setting Up the Stack Configuration” in the Using the
BayStack 450 10/100/1000 Series Switch guide.
Removing/Replacing Nonadjacent Units
To remove/replace nonadjacent units from an operating
stack, complete the following steps (see
Figure 15
):
1.
Remove the cascade cable from the Cascade A In
connector at unit 3.
2.
Remove the cascade cable from the Cascade A Out
connector at unit 3.
3.
Remove the unit (unit 3) and install the
replacement unit as required.
4.
Reconnect the cascade cables (removed in Steps 1
and 2) to unit 3.
Note:
Remove and replace the units individually
to avoid segmenting the stack configuration.