Installing the Model 8000 Remote Access Concentrator
Chapter 4 Troubleshooting Procedures
4-8
Activity T3: At the
Monitor Prompt
When the STAT and ATTN LEDs are on, the ROM monitor prompt is
displayed on the console terminal. Enter the boot command at the prompt.
If you do not enter a file name with the command, you are prompted to
do so.
Setup Mode Error States
describes the LEDs that are used to indicate errors at different
stages of the system startup process. If the RAC fails while testing the
hardware (state T2), the error condition is hardware failure TE2. A
description of each error condition follows
Table 4-5. Setup Mode Error LED States
Key:
●
On continuously
✕
Off
◆
Flashing regularly (about 1Hz)
Activity TE2:
Hardware Failure
The ROM diagnostics detected a RAC hardware problem requiring
service. Call the Technical Solutions Center.
Activity
STAT
Green
ATTN
Amber
TRAF
Green
TE2: Hardware Failure
◆
◆
✕
TE7: Booted Wrong Image
●
◆
✕