
A-73
Appendix A RAC Parameters
Managing Remote Access Concentrators Using Annex Manager
•
Dialinout
sets
mode
to
adaptive,
port_type
to
dialin
,
speed
to
115200
(or the highest speed that the hardware supports),
control_lines
to
both
,
input_flow_control
to
eia
,
output_flow_control
to
eia
,
need_dsr
to
disabled
,
bidirectional_modem
to
enabled
, and
broadcast_direction
to
port
.
•
Dialout
sets
mode
to
slave,
port_type
to
dialin
,
speed
to
115200
(or the
highest speed that the hardware supports),
control_lines
to
both
,
input_flow_control
to
eia
,
output_flow_control
to
eia
,
need_dsr
to
disabled
,
bidirectional_modem
to
enabled
, and
broadcast_direction
to
network
.
•
Autodetect
sets
mode
to
auto_detect
,
port_type
to
dialin
,
autobaud
to
enabled
,
speed
to
115200
(or the highest speed that the hardware
supports),
control_lines
to
both
,
input_flow_control
to
eia
,
output_flow_control
to
eia
,
need_dsr
to
enabled
,
bidirectional_modem
to
enabled
, and
broadcast_direction
to
port
.
•
Autoadapt
sets
mode
to
auto_adapt
,
port_type
to
dialin
,
autobaud
to
enabled
,
speed
to
115200
(or the highest speed that the hardware
supports),
control_lines
to
both
,
input_flow_control
to
eia
,
output_flow_control
to
eia
,
need_dsr
to
enabled
,
bidirectional_modem
to
disabled
, and
broadcast_direction
to
port
.
•
Ipx
sets
mode
to
ipx
,
port_type
to
dialin
,
autobaud
to
enabled
,
speed
to
115200
(or the highest speed that the hardware supports),
control_lines
to
both
,
input_flow_control
to
eia
,
output_flow_control
to
eia
,
need_dsr
to
enabled
,
bidirectional_modem
to
disabled
, and
broadcast_direction
to
port
.
You can set any parameter included in
port_modem_config
separately.
For example, you can choose
dialin
and then change the
speed
parameter to
57600
. This change affects
port_modem_config
in the
following way:
Each time you use a command that reads the
port_modem_config
value,
the RAC tries to match the individual parameter values to existing
port_modem_config
settings. If parameter values match, Annex
Manager displays the appropriate value for
port_modem_config
. If you
changed one or more parameter values so that they do not match
port_modem_config
values, Annex Manager displays
unknown
.
Unknown
appears only under this circumstance. You cannot choose
unknown for
port_modem_config
.
Содержание 5391
Страница 6: ...Managing Remote Access Concentrators Using Annex Manager vi ...
Страница 16: ...Managing Remote Access Concentrators Using Annex Manager About This Guide xvi ...
Страница 36: ...Managing Remote Access Concentrators Using Annex Manager Chapter 2 Creating and Using RAC Lists 2 10 ...
Страница 148: ...Managing Remote Access Concentrators Using Annex Manager Chapter 6 Viewing and Changing SNMP Information 6 4 ...
Страница 174: ...Managing Remote Access Concentrators Using Annex Manager Chapter 7 Configuring RAC Parameters 7 26 ...
Страница 190: ...Managing Remote Access Concentrators Using Annex Manager Chapter 9 Configuring SNMP Traps 9 4 ...
Страница 296: ...Managing Remote Access Concentrators Using Annex Manager Appendix A RAC Parameters A 106 ...
Страница 314: ...Managing Remote Access Concentrators Using Annex Manager Appendix B Configuring and Editing Scripts B 18 ...
Страница 342: ...Managing Remote Access Concentrators Using Annex Manager Appendix D Help Reference D 8 ...