EN
USER MANUAL
XTA
14
7.2 PARAMETER MENU
MENU
SUB MENU
DESCRIPTION
F0 CAL
Calibration.
F 1 r ES
3000
Set external resolution
6000
dUAL - i
dUAL - r
F 2 CAP
3KG
Set scale capacity
6KG
15KG
30KG
F 3 PDEC,
0
Set Price Decimal Point
0. 0
0. 00
0. 000
0. 0000
F 4 PdESC
F E
Set unit Price to FIX or FLOATING
FLoAT
F 5 SPEED
SLOW
To select A/D speed
MEDIUM
FAST
F6 Min coin
1 2 5 0
Select minimum coin
F7 SCSIUE
tare
ON
Multi - Tare function ON
OFF
Multi - Tare function OFF.
F8 ISN
This display will show XXXXX for indicating the internal counts.
F9 Gra
To set your local gravity value.
F10 Reset
Factory default settings
F11 rS232
ModE
The scale RS232 protocol will be determined by the Baud & Pr settings
oFF
RS232 function disable
Cont
Continues data transmission
StC
Stable data transmission (sending continue frame)
toLE do
Protocol type 1: Toledo
nC iE
Cr
Protocol type 2: NCI-ECR
nC iG
En
Protocol type 3: NCI-General
tEC
Protocol type 4: TEC
EASY
Protocol type 5: Easy Weigh
POS
Protocol type 6: POS
bAUd
Set baud rate to (1200/2400/4800/9600/19200/38 400/115200)
Pr Bn 1
8 data bits, no verify, 1 stop bit
Pr 7E1
7 data bits, Even verify, 1 stop bit
Pr 7o1
7 data bits, Odd verify, 1 stop bit