4 . O P E R A T I O N S
KEY
FUNCTION
ON/OFF
Turn on/off power of the balance
FUNCTION
Call up menu (keep key pressed un!l UNIT appears)
SET/TARE
- Confirm se#ngs in the menu.
- Save and exit menu.
- Tare weight.
UNIT/COUNT
- Select weighing unit.
- Change se•ngs in the menu.
- Parts coun•ng.
HOLD/PRINT
- Display hold.
- Calculate weighing data via interface.
- Change se•ngs in the menu.
ZERO
Zero balance.
4 . 1 . W E I G H I N G
Turn on the balance using the
>
ON/OFF
key.
The balance will perform self-test for few seconds. When the zero display appears, the balance is
>
ready for operations.
Important: If the display not showing zero, press the
ZERO
key.
Place objects onto the center of pan. Take care that the weighed material should not touch the
>
balance housing.
Now the weight is displayed. Once the reading is stable, the weighing unit (e.g.
>
g
or
kg
) will appear
on the right-hand side of the display.
If the objects are heavier than the weighing capacity, the display will show
>
Error
(=overload).
4 . 2 . TA R I N G
Turn on the balance using the
>
ON/OFF
OFF key and wait for the
ZERO
display.
Put the tare vessel on the weighing plate and press the
>
SET/TARE.
key. The balance display goes to
zero. The weight of the vessel is now saved.
The taring process can be repeated any number of times, e.g. when adding several components for a
>
mixture (adding).
The limit is reached when the total weight reaching full capacity of the balance. After removing the
>
taring vessel, the total weight is displayed as negative reading.
After finishing the weighing process, press the
>
SET/TARE
key again, the balance display goes back to
ZERO
.
4 . 3 . P R E • TA R E F U N C T I O N
Using this function the weight of a tare vessel can be stored.
This value also remains saved if the balance meanwhile has been switched off and switched on again.
Turn on balance using the
>
ON/OFF
key and wait for the zero display.
Put tare vessel on the weighing plate. Press the
>
UNIT/COUNT
key until balance displays
5 PCS
.
Press the
>
UNIT/COUNT
key 6 times until
PtArE
flashes on the display. By actuating the
SET/TARE
key,
the current weight on the weighing plate is saved as PRE-Tara weight.
To switch off this function, unload the weighing plate. Press
>
ZERO
key if display is not showing zero.
Press the
>
UNIT/COUNT
key until balance displays
5 PCS
.
Press the
>
UNIT/COUNT
key 6 times until
PtArE
flashes on the display. By actuating the
SET/TARE
key,
the stored PRE-Tare weight is deleted.