background image

Supplied By www.heating spares.co  Tel. 0161 620 6677

Changing Components – Page 8

The following components can be removed as described
below after first removing the outer case. Turn off the gas
and withdraw the plug from the electrical supply before
removing the outercase.

ENSURE THAT THE FIRE IS COLD
GAS CONTROL TAP

 (Flame Failure Device)

(a)

Greasing the tap plug

 (Fig.13). Pull off the plastic cap

and then the spark electrode lead from the piezo unit
and undo the two set screws and washers securing the
niting plate to the tap body.

Remove the piezo unit complete with the gas tap
spindle and spring. Now remove the plug and apply
suitable grease sparingly, e.g. Kluber N322B.
(Excessive grease may block the gasways). On re-
assembling care must be taken to ensure that both the
plug and spring are in place.

(b)

To exchange the component 

(Fig. 11). (Disconnect

the gas supply and remove the fire from the fireplace.)
Pull off the plastic cap and disconnect the spark
electrode lead from the piezo unit. Disconnect the four
tubes at the gas tap. Disconnect the thermocouple from
the gas tap. Remove the 3 screws securing the gas tap
bracket to the inner case and remove the complete
assembly. Remove the locknut holding the gas tap to
the bracket and remove the gas tap.

On re-assembly ensure that the spark electrode lead is
correctly fitted and that the plastic cap is pushed on the
piezo unit. Ensure that the pilot filter supplied with the new
tap is fitted.

GLASS FRONT PANEL

 (Fig. 10)

(a)

Ensure that the glass front panel is cold.

(b)

Slide the glass front panel retaining clamps sideways.

(c)

Lift the glass front panel bottom edge out of the locating
channel and carefully remove the glass front panel.

On re-assembly ensure that:

(a)

The glass front panel sealing rope is replaced if it is in
anyway damaged.

(b)

The glass front panel is replaced if it is in anyway
damaged or cracked.

NOTE:  This is a heat resistant glass front and must not
be replaced by ordinary glass.

Coal Bed

 (Fig. 10)

Remove the glass front panel as described above.
Remove the coal bed by lifting it carefully away from the
Locating pins.

On re-assembly ensure that the coal bed is correctly located
over the locating pins.

BURNER

 (Figs. 10,11 and 12)

(a)

Remove the glass front and coal bed as described
above.

(b)

Pull back the sleeve and disconnect the electrode lead
from the electrode.

(c)

Disconnect the compression nuts from the injectors.

(d)

Remove the screw securing the electrode/
Thermocouple assembly to the burner and retract

through the combustion box.
(e)

Remove the two screws securing the burner.

(f)

Slide the burner out above the glass locating channel.

(g)

Remove the injectors from the burner.

PILOT/THERMOCOUPLE/ELECTRODE
ASSEMBLY

 (Fig.12)

NOTE:  The thermocouple cannot be changed as an
individual component. The complete assembly must be
changed in the event of one or other component
failure(s).

(a)

Disconnect the gas supply and remove the fire from the
fireplace.

(b)

Pull back the sleeve and disconnect the lead from the
electrode.

(c)

Undo the nut on the pilot feed pipe.

(d)

Remove the screw holding the assembly to the bracket.

(e)

Undo the thermocouple from the gas tap.

(f)

Remove the assembly from the fire.

(g)

On re-assembly, shape the thermocouple in a similar
manner to the original.

ELECTRO MAGNETIC UNIT

 (Fig.11 and 13)

(a)

Remove the gas tap as explained in Gas Control Tap
section (b).

(b)

Remove the electro magnet retaining nut and withdraw
the electro magnet unit.

PIEZO UNIT

 (Fig. 13)

(a)

Pull off the plastic cap and disconnect the spark
electrode lead from the piezo unit.

(b)

Undo the tabs on the rear of the piezo unit and remove.

(c)

Replace the piezo unit twisting the tabs to retain it firmly
in position. Re-connect the spark electrode lead and re-
fit the plastic cap.

RESISTOR

(a)

Check that the mains lead is disconnected.

(b)

Remove the screw-securing the light bulb cover and lift
upwards.

(c)

Remove the clip securing the resistor to the cover and
disconnect the 2 wires.

(d)

Replace the Resistor and reassemble in reverse order.

LIGHT SWITCH

Pull off the two flag terminals from the switch noting their
relative positions. Press together the retaining arms on the
rear of the switch and remove from the bezel. Replace the
switch and terminals.

Содержание Solaire Super

Страница 1: ...heating spares co Tel 0161 620 6677 Please leave these Instructions with the user Baxi Solaire Super Gas Fire Natural Gas Comp No 236216 10 95 Baxi Solaire Super G C No 32 077 36 Installation And Servicing Instructions ...

Страница 2: ...above the fire provided that it does not exceed 150mm 6in deep and is at least 100mm 4in above the top of the fire A clearance of 75mm 3in is required at each side of the fire for access during servicing b Fireplace opening At the height of the flue outlet the fireplace should have a minimum dimension of 100mm 4in from the front face of the opening to the fireplace back brick Fig 3 There must be a...

Страница 3: ...EGULATIONS The mains lead has the billowing specifications 16 0 2mm 3 core PVC covered PVC insulated wire to BS 6500 IMPORTANT Mains lead wires Green and yellow Earth Blue Neutral Brown Live FOR THE MAINS PLUG USE A 3AMP FUSE The appliance is supplied with approximately 3 metres of wire and a mains plug A longer cable may be fitted as follows a Remove the socket and plug from the cable supplied b ...

Страница 4: ...T THE FIRE SEEK EXPERT ADVICE HEARTH FIXING Fireplace or Surround a Fit the fire backing plate to the fire using the M5 x 8mm thread forming screws provided The backing plate may be screwed to the wall for extra support if necessary Fig 6 b Position the fire minus the outer case against the closure plate and determine the position of the gas connection c Adjust the feet to level the fire Fig 7 Che...

Страница 5: ...Check that the ignition is satisfactory e Check the fire pressure with the control knob turned fully anti clockwise The pressure should be 12 5mbar 1 0mbar 5 0 in wg 0 4 in wg No adjustment is provided on the fire Turn the control knob to the OFF position Remove the pressure gauge and refit the pressure test point sealing screw Turn the fire on full again and check for gas soundness using a suitab...

Страница 6: ...entilation hole at the bottom of the closure plate is not covered 1 Remove the outer case for access to all controls a Pull off the control knob b Remove the cover panel under the front of the fire by grasping it firmly by its side edges and pulling forwards c Remove the two case securing screws Fig 7 d Lift the case away from the heat exchanger 2 Remove the glass front panel Fig 10 a Ensure that ...

Страница 7: ...Supplied By www heating spares co Tel 0161 620 6677 Commission the Fire Page 7 ...

Страница 8: ...t panel as described above Remove the coal bed by lifting it carefully away from the Locating pins On re assembly ensure that the coal bed is correctly located over the locating pins BURNER Figs 10 11 and 12 a Remove the glass front and coal bed as described above b Pull back the sleeve and disconnect the electrode lead from the electrode c Disconnect the compression nuts from the injectors d Remo...

Страница 9: ...8 040955 C Knob Gas Tap Control 156 430 234544 D Flame Failure Device Gas Tap 378 916 235335 E Piezo Unit Vernitron 66111 393 734 042941 F Encapsulated Unit Concentric TE 418 384 248 082462 G Injector F11 Cat 18 230 381 879 092133 H Burner Aeromatic Baxi Special 155 949 043210 I Oxy pilot Assembly 350mm SIT OP 9402 378 914 236204 J Lead Electrode 400mm 378 911 236209 K Coal Bed 156 429 235149 L Fi...

Страница 10: ...Supplied By www heating spares co Tel 0161 620 6677 Fault Finding Chart Page 10 11 BAXI SOLAIRE SUPER Gas Type G20 Natural Gas Click here for Helplines ...

Отзывы: