Appliance Details – Page 3
Dimensions
HEIGHT
WIDTH
DEPTH
INPUT
OUTPUT
SETTING PRESSURE
(COLD)
GAS
ELECTRICAL
(MAIN INPUT)
RESISTOR
BURNER
PILOT IGNITION
WEIGHT
HEIGHT FROM HEARTH TO
TOP OF FLUE SPIGOT
TAP
BURNER INJECTORS
Projection in room
706mm (27
13
/
16
in)
696mm (27 ½ in)
317mm (12 ½ in)
High - 5.42kW (18,500 Btu/h)
Low - 2.10kW (7,200 Btu/h)
High - 3.47kW (11,840 Btu/h)
12.5 mbar ± 1.0 mbar
5.0 in w.g. ± 0.4in w.g.
Natural Gas
230 volts ~ 50 Hz - 3A - 120W
68 ohms
Aerated - Duplex
Piezo Unit - Spark Gap
2.5mm - 4.0mm
40kg (88 Ibs)
489mm (19 ¼ in)
Duplex with rotary piezo and
flame failure device operated
by Oxy-pilot
230
ELECTRICAL CONNECTION
THIS APPLIANCE MUST BE EARTHED
ALL EXTERNAL WIRING BETWEEN THE APPLIANCE AND
THE ELECTRICAL SUPPLY SHALL COMPLY WITH
CURRENT I.E.E. REGULATIONS. The mains lead has the
billowing specifications: 16/0.2mm - 3 core PVC covered -
PVC insulated wire to BS 6500.
IMPORTANT:
Mains lead wires:
Green and yellow – Earth
Blue – Neutral
Brown – Live
FOR THE MAINS PLUG USE A 3AMP FUSE. The appliance
is supplied with approximately 3 metres of wire and a mains
plug. A longer cable may be fitted as follows:
(a)
Remove the socket and plug from the cable supplied.
(b)
Re-assemble on the longer cable ensuring both socket
and plug are wired correctly.
If a different mains plug is used from the one supplied with
appliance proceed as follows:
The wire which is coloured green and yellow must be
connected to the terminal in the plug which is marked
by the letter E’ or by the earth symbol
or coloured
green or green and yellow. The wire which is coloured
blue must be connected to the terminal which is
marked with the letter ‘N’ or coloured black. The wire
which is coloured brown must be connected to the
terminal which is marked with the letter ‘L’ or coloured
red.