INSTRUCTIONS FOR THE INSTALLER
3)
Turn the control knob 7 to display the values of the following parameters in sequence:
A0:
domestic hot water output temperature (in °C);
A1:
outdoor temperature (in °C);
A2:
the value (%) of the PWM signal to the fan (reserved for service engineers);
A3:
fan speed (in rpm) x 100 (reserved for service engineers);
A4:
central heating water output setpoint temperature (in °C);
A5:
flue control NTC temperature;
A6:
diagnostic information;
A7:
not used;
A8:
manufacture information;
A9:
manufacture information.
Figure 22
0402_2503
~ 5 seconds
4) To exit “INFO” mode, simply turn control knob 6 fully anti-clockwise (see step 1 above) and repeat step 2.