54
7113868.01 - en
INSTRUCTIONS FOR FITTERS
27. CONNECTING THE EXTERNAL PROBE
Figure 16
0610_1301 / CG_1855
CN 5
For special areas, where the water is harder than 25 °F (1 °F = 10 mg calcium carbonate per litre of water), install a polypho-
sphate dispenser or an equivalent treatment system, compliant with current regulations.
The DHW expansion vessel should be mounted if:
r UIFQSFTTVSFPGUIFXBUFSTVQQMZPSMJGUJOHTZTUFNJTTVDIBTUPSFRVJSFUIFJOTUBMMBUJPOPGBQSFTTVSFSFEVDFS QSFTTVSF
higher than 4 bar)
r BOPOSFUVSOWBMWFJTàUUFEUPUIFXBUFSTVQQMZMJOF
r UIFXBUFSTVQQMZOFUXPSLJTJOTVGàDJFOUGPSUIFFYQBOTJPOPGUIFXBUFSDPOUBJOFEJOUIFTUPSBHFCPJMFSBOEJUJTOFDFTTBSZ
to use the DHW expansion vessel.
Tip
For the efficient operation of the expansion vessel, the pressure of the water supply must be lower than 4 bar. If it is not,
install a pressure reducer. Adjust the pressure reducer to obtain a water supply pressure less than 4 bar.
Figure 15