60
925.916.2 - GB
InstructIons pertaInInG to the InstaLLer
Luna3 sYsteM ht 1.240 Mp
Gas consumption at15 °c
G20 - 2h - 20 mbar
G31 - 3p - 37 mbar
1013 mbar
PCI
34.02 MJ/m
3
46.3 MJ/kg
Consumption at max. heat output
2.61 m
3
/h
1.92 kg/h
Consumption at min. heat output
0.74 m
3
/h
0.54 kg/h
table 2b
Luna3 sYsteM ht 1.180 Mp
Gas consumption at 15 °c
G20 - 2h - 20 mbar
G31 - 3p - 37 mbar
1013 mbar
PCI
34.02 MJ/m
3
46.3 MJ/kg
Consumption at max. heat output
1.84 m
3
/h
1.35 kg/h
Consumption at min. heat output
0,44 m
3
/h
0,33 kg/h
table 2c
Luna3 sYsteM ht 1.330 Mp
Gas consumption at 15 °c
G20 - 2h - 20 mbar
G31 - 3p - 37 mbar
1013 mbar
PCI
34.02 MJ/m
3
46.3 MJ/kg
Consumption at max. heat output
3.59 m
3
/h
2.64 kg/h
Consumption at min. heat output
1,06 m
3
/h
0.78 kg/h
table 2a
cLocKWIse
parameters 608
parameters 611
Gas boiler model
regulation screw
(%) (rpm)
(rpm)
(V) turns
Gas G20
Gas G31
Gas G20
Gas G31
LUNA3 SySTEM HT 1.330 MP
3
50
35
4200
3500
LUNA3 SySTEM HT 1.240 MP
2
55
35
4600
4000
LUNA3 SySTEM HT 1.180 MP
1
40
40
3900
3350