41
925.916.2 - GB
InstructIons pertaInInG to the user
3.2 settIng the tIme
a)
Press either of the keys to access the programming function;
the display will show the letter P followed by a number (program line);
b)
press the keys until the display shows P1, referring to the time to be set;
c)
press the keys to set the time; on the display, the letter P will start to flash;
d)
press the key to save and exit the programming function;
- Press the key (3-figure 1) to set the maximum domestic hot water temperature;
- Press the keys to set the temperature required;
- press either of the keys (1 or 10 - figure 1) to save and return to the main menu.
3.4 – settIng the maxImum DomestIC hot water temperature
020503_0700
Figure 3
- Press the key (2-figure 1) to set the central heating water temperature;
- Press the keys to set the temperature required;
- press either of the keys (1 or 10 - figure 1) to save and return to the main menu.
note –
With the outdoor sensor probe connected, the key (2 - figure 1) can be used to shift the central heating
curve. Press the keys to decrease or increase the room temperature in the premises to be heated.
3.3 settIng the maxImum Central heatIng temperature
3-5.1. setting the daily times for central heating mode operation
- Press either of the keys to access the programming function;
a)
press these keys until the display shows
p11
, referring to the program start time;
b)
press the keys to set the time;
-
press the key; the display will show
p12
, referring to the program end time;
-
repeat the operations described in points
a
and
b
until the third and last cycle is reached
(program line
p16
);
-
press the key to save and exit from the programming function.
3-5.2. setting the daily times for domestic hot water mode operation
- As supplied by the factory the appliance is set up with the domestic hot water function always enabled and the domestic
hot water programming function disabled.
The instructions for enabling this program are given in chapter 17, which is addressed specifically to installers (
parameter
H91
).
If the program is enabled carry out the operations described in point 3-5.1 for program lines
31