41
7216549.01 - en
INSTALLATION AND OPERATING MANUAL
The appliance is sold complete with electrical connections and power cable.
This machine is only electrically safe if it is correctly connected to an efficient earth system in compliance with current
safety regulations.
Connect the appliance to a 230V single-phase earthed power supply using the supplied three-pin cable, observing cor-
rect LIVE (L) - NEUTRAL (N) polarity.
Use a double-pole switch with a contact separation of at least 3 mm.
When replacing the power supply cable, fit a harmonised “HAR H05 VV-F” 3x1 mm
2
cable with a maximum diameter of
8 mm.
9. ELECTRICAL CONNECTIONS
9.1 ACCESS TO THE POWER SUPPLY TERMINAL BLOCK
INSTALLATION INSTRUCTIONS:
ELECTRICAL CONNECTIONS
Figure 7: Electric fuses
940225_0715
fuse
terminal block
• Disconnect the appliance from the mains power supply using the two-pole switch.
• Remove the door of the casing using the supplied square key.
• Make sure that the switch indicator light is off.
• Loosen the screws on the cover of the electrical box and remove it.
• The 2A fast-blowing fuse is incorporated in the power supply terminal block.
(L) = LIVE brown
(N) = NEUTRAL blue
= EARTH yellow-green