ZONE SYSTEM WITH INSTALLATION OF THE REMOTE CONTROL
The electrical connection and the adjustments required to manage a system divided into zones with use of the Remote Control
GLIIHUV DFFRUGLQJ RQ WKH DFFHVVRULHV FRQQHFWHG WR WKH ERLOHU 7R LQVWDOO DQG FRQ¿JXUH VHH WKH LQVWUXFWLRQV RI WKH
Expansion
Module
supplied as an accessory.
ADJUSTING THE TEMPERATURE OF THE HIGH TEMPERATURE HEATING SYSTEM
To avoid frequent starting and stopping, raise the minimum temperature setpoint of the boiler in the heating mode by setting
parameters
740
WRQRWOHVVWKDQ&XVLQJWKHSURFHGXUHGHVFULEHGLQSRLQW
B
.
TEMPERATURE ADJUSTMENT ON
LOW TEMPERATURE HEATING SYSTEM
)RUDORZWHPSHUDWXUHV\VWHPVXFKDVXQGHUÀRRUKHDWLQJUHGXFHWKHPD[LPXP&+WHPSHUDWXUHVHWSRLQWRQWKHERLOHUE\VHWWLQJ
parameter
741
(point B
)
WRDYDOXHQRWJUHDWHUWKDQ&
11.2.2 EXTERNAL SENSOR
7R FRQQHFW WKLV DFFHVVRU\ VHH ¿JXUH WR VLGH WHUPLQDOV
4
-
5
)
and the instructions supplied with the sensor.
With the External Sensor connected,
on the boiler
control panel move the set climate curve
Kt
in parallel (see
annex
“SECTION” E
and parameter
P03
in the table in section
14). To increase room temperature press
+
, to decrease press
-
.
SETTING THE “Kt” CLIMATE CURVE
To set the required kt climate curve, proceed as follows:
Access the menu as described in section 14.
Select parameter
P03
.
Select the climate curve from among those available, see the curve chart in annex
“SECTION” E
at the end of this manual
(the preset curve is 1.5).
KEY TO CURVE CHART Kt -
“SECTION” E
Flow temp
Outside temp
11.2.3 HEATING SYSTEM PUMP
Install the system pump downline from the hydraulic separator. Choose the pump according to the required system capacity/head
characteristics (see annex
“SECTION” F
).
11.2.4 EXTERNAL STORAGE BOILER
The boiler can be electrically connected to an external storage boiler. A diagram of the hydraulic connection of the external storage
boiler is shown in annex
“SECTION” F
. Connect the storage boiler pump to terminals
4-5
of the
M3
terminal block (see annex
“SECTION” B
). Install the storage boiler downline from the hydraulic separator. Use the sensor supplied as an accessory and
connect it to terminals
9-10
of terminal block
M2
(see annex
“SECTION”
B
). Make sure that the exchange capacity of the storage
boiler coil is appropriate for the power of the boiler.
EXTERNAL SYSTEM MANAGEMENT MODULES
The boiler can independently manage up to three heating circuits by using external accessories such as room units, remote
controls and external modules (AGU 2.550 and AVS 75). The boiler electronics also comprises a wide range of functions for
personalising and managing various system types. To assure correct system operation, a number (from 1 to 3) must be assigned
to each accessory in order to allow the boiler board to recognise it. Consequently, carefully read the instructions provided with the
accessories.
11.2.5 MIXED ZONES (“SECTION” F)
A mixed zone can be managed using the
AVS75
external module, supplied as an accessory. This accessory can manage: a zone
pump, a mixing valve, a temperature sensor, a limit thermostat and a room thermostat. To connect the components and adjust the
system read the manual provided with the accessory.
11.2.6 BOILERS IN A CASCADE CONNECTION (“SECTION” F)
The
AVS75
external unit, supplied as an accessory, is used to manage a heating system with up to 16 boilers connected in a
cascade arrangement and a possible separate storage boiler providing domestic hot water. This accessory, connected to one of
the cascade boilers, can directly control the circuit components up to a maximum of 3 independent relay outlets, 2 temperature
sensors, 1 high voltage limit thermostat connector and one 1 control input (e.g.: room thermostat). The system also requires an
OCI 345
interface on each boiler comprising in the cascade arrangement. To adjust boiler parameters see section “PARAMETER
SETTINGS”. To connect the components and adjust the system read the manual provided with the accessory.
Содержание LUNA DUO-TEC MP 1.110
Страница 82: ...7115213 01 4 10 14 82 S E C T I O N A 20 19...
Страница 86: ...7115213 01 4 10 14 86 S E C T I O N C...
Страница 87: ...87 S E C T I O N C 7115213 01 4 10 14...
Страница 88: ...7115213 01 4 10 14 88 S E C T I O N D 25 mm...
Страница 89: ...89 S E C T I O N D 7115213 01 4 10 14 A B PD P PP C D PD P PP E F PD P PP G PD P PP H PD P PP I PD P PP PD P...
Страница 91: ...91 S E C T I O N G 7115213 01 4 10 14 AGU 2 550 CR_0349 CR_0349 AVS 75 S E C T I O N F...
Страница 92: ...7115213 01 4 10 14 92 S E C T I O N G CG_2482 Tmax 50 C S E C T I O N F...
Страница 93: ...93 7115213 01 4 10 14...
Страница 94: ...7115213 01 4 10 14 94...
Страница 96: ...7115213 01 4 10 14 DVVDQR GHO UDSSD 9 7 9LD 7UR HWWL 6HUYL LR FOLHQWL WHO 7HOHID ZZZ ED L LW...