12.0 Care of the Boiler

20

© Baxi Heating UK Ltd 2011

12.1

Cleaning the Outer case

The painted panels should be wiped with a damp cloth and
then dried completely. 

DO NOT USE ABRASIVE

CLEANING AGENTS.

12.2

Maintenance 

1. The appliance MUST be serviced annually by a Baxi
authorised engineer.

2. Before electrically isolating the appliance: remove all demands
for heat and ensure the engine has disconnected from the grid.
(Power = 0 kW) This will protect the engine from the stresses
produced by disconnecting during electricity generation.

12.3

Condensate drain 

The condensate drain, located at the bottom of the appliance,
must not be modified or blocked. Blockage will cause the
appliance to shut down. 

12.4

Protection & Precaution

1. The appliance incorporates frost protection for itself only,
fitted as standard. If the system has a i-THINK Controller
configured as a Room Sensor mounted in a cradle on a wall
then the central heating system will also be protected. 

2. In cold weather, if you are going away, turn the appliance off
at the time switch ONLY. Leave the mains supply switched ON.
This will ensure protection by the frost thermostat. Alternatively
use the Holiday Mode (see Section 7.9).

3. If a system frost thermostat has been fitted (your installer will
be able to advise you), then to operate correctly and protect
your system, the gas and electricity must be left on and the
appliance set in the central heating mode.

4. The boiler incorporates an integral pump protection feature
which continually monitors the time since the pump last
operated. To prevent seizure, the pump will operate for
approximately 1 minute if it has not run in the last 24 hours.

12.5

Fault Indication

1. If a fault occurs on the boiler an error code may be shown
on the facia display.

12.6

In an Emergency

If a gas leak occurs or is suspected, the boiler can be
isolated at the inlet valves as follows;

1. Using a suitable open ended spanner, turn the square
nut on the gas tap through 90° (

1

/

4

turn) in a clockwise

direction to isolate the gas supply at the boiler.

2. Call your Installer or Service Engineer as soon as
possible.

Gas Service Cock

View from under appliance

Off Position

On Position

Test Nipple

If you smell gas

Do not operate light switches
Do not operate any electrical equipment
Do not use a telephone in the hazardous area
Extinguish any naked flame and do not smoke
Open windows and doors in the hazardous area
Turn off the gas supply at the meter
Warn any other occupants and vacate the premises
Telephone the National Gas Emergency Service on:-
0800 111 999

Faulty boiler

If it is known or suspected that a fault exists 
on the boiler, it must not be used until the fault 
has been corrected by a competent person.

IMPORTANT

If the boiler operates on LPG (Propane). Familiarise
yourself with any control and isolation valves. If in
doubt consult your installer about the operation of
these devices.

Warning !

Содержание Ecogen 24

Страница 1: ...erating Instructions Important Warranty Information Please keep these instructions in a safe place If you move house please hand them over to the next occupier Ecogen 24 1 0 Gas Fired Wall Mounted Con...

Страница 2: ...e for Operating Quick Reference Guide This appliance contains a pressure vessel filled with Helium to 23 bar Do not strike drop drill or puncture the vessel Do not unbolt any of the covers or flanges...

Страница 3: ...Easy Menu Button Commonly required functions are available more quickly via the Easy Menu Button To access press the Easy Menu Button and turn the Selector Button to scroll through confirm your selec...

Страница 4: ...tic 7 All interactions with the appliance are through the removable i THINK Controller mounted either on the front of the appliance or on a remote wall cradle 2 2 Important Notes 1 Read and follow the...

Страница 5: ...estic hot water are set to 24hr operation see sections 7 1 and 7 4 choose On in both cases 4 Refer to the instructions for the existing programmers for setting the timed periods and the room temperatu...

Страница 6: ...tton and the minute number flashes Turn Button to the required minute Press the Selector Button Hours minutes 11 30 Set time and date Day month 05 06 Set time and date Turn the Selector Button clockwi...

Страница 7: ...day Set time and date Information The basic display is shown If the basic display is not showing press the MENU button until the basic display is shown Press the MENU button Time hot water Operator se...

Страница 8: ...time will flash Turn the Button to the required time Press the Button to select Press the Selector Button and the 3rd Time ON time will flash Turn the Selector Button to the required time Press Butto...

Страница 9: ...If the basic display is not showing press the MENU button Press the MENU button Holidays heating CH1 Time central heating CH1 Time hot water Mon Sun Select days Time hot water Turn the Selector Button...

Страница 10: ...e Button to the required time Press the Button to select Press the Selector Button and the 3rd Time ON time will flash Turn the Selector Button to the required time Press Button to select STEP 11 STEP...

Страница 11: ...ntil the next programmed comfort period when the setpoint will revert to the permanent comfort setpoint see Section 7 8 7 3 Optimum start Instead of the heating starting at the Programmed times the op...

Страница 12: ...tary burner to light during DHW demands e Eng bu only may be reselected at any time 7 6 Adjusting the DHW Cylinder Temperature 1 If the DHW Cylinder is fitted with a temperature sensor the cylinder se...

Страница 13: ...ctor Button 7 8 Adjusting the Room temperature setpoint 1 The room temperature setpoint may be adjusted temporarily as long as the appliance is not in standby or protection mode 2 From the main screen...

Страница 14: ...locked appears b In this state any alterations can be made until returning to the standard screen when the programming lock is activated again c To remove the programme lock permanently whilst tempora...

Страница 15: ...months 2 Telephone customer service 8 10 Selecting Diagnostics engine The following information is also available by pressing the menu button and selecting Diagnostics engine by pressing the Selector...

Страница 16: ...reset can only be carried out on the i THINK Controller when it is not a Room Sensor 2 To perform a user reset a on the 5 LED Receiver press the reset button at the bottom of the unit after a few seco...

Страница 17: ...your boiler 6 Your boiler should have the following minimum clearances for Safety and Maintenance Top 200mm Bottom 200mm Left side 5mm Right Side 60mm Front 5mm In Operation 450mm For Servicing 7 If y...

Страница 18: ...AR AR 259 CJC sensor Fault cold junction compensation sensor AR 261 Loss of Engine flame No flame after five ignition tries in Engine UR 262 Loss of Supplementary flame No flame after five ignition t...

Страница 19: ...e burner BCU isn t consistent AR 423 BCU Supp bu inconsistent Transmitted state of the supplementary burner BCU isn t consistent AR 424 Rep loss of flame Eng bu Repeated loss of flame engine burner UR...

Страница 20: ...ity must be left on and the appliance set in the central heating mode 4 The boiler incorporates an integral pump protection feature which continually monitors the time since the pump last operated To...

Страница 21: ...inside back pages of the installation instructions supplied with the product and that you have signed it to say that you have received a full and clear explanation of its operation The installer is l...

Страница 22: ...14 0 Notes 22 Baxi Heating UK Ltd 2011...

Страница 23: ...14 0 Notes 23 Baxi Heating UK Ltd 2011...

Страница 24: ...trations provided in this leaflet have been carefully prepared but we reserve the right to make changes and improvements in our products which may affect the accuracy of the information contained in t...

Отзывы: