9.0 Resetting the Boiler
16
© Baxi Heating UK Ltd 2011
9.1
Exceptional conditions
1. In exceptional cases, the display will show an error screen see
diagram opposite.
2. With the following information: -
An error number
a short description of the error
The display may or may not show a flashing spanner, a
flame crossed out or both depending on whether the unit
is on the appliance or the wall.
3. Pressing the menu button will return the i-THINK Controller
to the standard display which will now show the following
symbol -
E
which indicates that an error or fault has occurred
in the appliance. After 1 minute the display will automatically
revert to the error screen.
4. Press the menu button twice to revert to the error display
immediately. A list of error codes is shown in section 11.1. This
list contains both user reset and automatic reset codes.
Automatic codes are given here as they are capable of clearing
automatically and do not necessarily indicate that a service visit is
required.
9.2
Automatic reset
1. If a flashing spanner is shown on the i-THINK Controller the
error may reset once the condition has cleared. Many of these
automatic reset errors are connected with temperature sensors
of both the system and the appliance and once the appliance has
cooled it may restart. If the problem persists where the same
error code is repeatedly displayed or the error will not clear you
should call for a service engineer.
9.3
User reset
1. A user reset can only be carried out on the i-THINK
Controller when it is not a Room Sensor.
2. To perform a user reset:-
a) on the 5 LED Receiver, press the reset button at the bottom
of the unit, after a few seconds the red flashing LED will go out.
b) on the i-THINK Controller reset appears, press the Selector
Button twice, after a few seconds the error symbol should
disappear.
3. The error will clear and the appliance will restart if there is a
demand for heat as long as the error condition has cleared. The
user error codes give an indication of possible problems which
the user may be able to rectify such as accidental isolation of
either the gas supply (error 261and 262) or the central heating
circuit, pump problems etc (error 275 and 276).
4. If the error returns the fault condition is still present.
9.4
Service reset
When a flashing spanner is accompanied by a crossed out flame
symbol on the appliance, a fault has occurred which requires the
presence of a service engineer. When ringing the Heateam
Service Department to request a service engineer please quote
the error code and accompanying message.
Menu
Button
04. November 2008 08:50
Tuesday
164:Flow press switch HC
Error
157: Boiler flow thermostat
Reset ?
Error
Yes
157: Boiler flow thermostat
Reset ?
Error
04. November 2008 08:50
Tuesday
To reset
- Press the Selector
Button and the Yes / No
mode will appear. While
flashing turn the Button to
toggle between Yes and No.
Select Yes and press the
Selector Button to select.
266:Fan Fault
Error
20:Boiler sensor 1
Error
5 LED-red light
Flashes
Flashes
On
i-THINK
Controller
Reset Type
Auto
User
Service
Selector Button
i-THINK Controller
Easy Menu Button