GAS CONSUMPTION

Has a maximum natural gas input of 5.6kW (Gross)
Has a maximum natural gas output of 4.0kW 

Has a minimum natural gas input of 1.57kW (Gross)
Has a minimum natural gas output of 1.0kW 

OPERATING YOUR FIRE

The Oxysafe flame sensing and flue blockage safety system.

For your safety, this appliance is fitted with a flue blockage safety device that will shut
down the appliance in the event of abnormal flue conditions. 

This device is NOT a

substitute for an independently mounted Carbon Monoxide detector. 

The device will also automatically shut off the gas supply to the fire if the pilot flame
goes out due to lack of oxygen or for any other reason.

If this device starts to repeatedly shut off the gas, get expert advice.

This device incorporates a probe that senses that the heat from the pilot flame is correct.
If this probe is cool, the device will prevent any gas flow unless the control knob is held
down at the ignition position.
If, for any reason, the flames go out when the fire is hot or if the fire is turned off when
hot, always 

wait at least three minutes before attempting to relight

.

To light the fire (Manual ignition).

The control is shown in Figure 2.

!

Depress the control knob and turn anticlockwise

towards the 1/IGN position. A spark should be
generated at the pilot while turning. The spark should
ignite the pilot. 

If it does not

, keeping the knob

depressed, continue to turn the knob anticlockwise. A

second 

spark should ignite the pilot. The pilot flame

can be seen through the opening immediately below
the right hand centre radiant (See figure 3). 

Page 7

OWNER GUIDE

© 

Baxi Heating U.K. Limited 2006.

PLEASE NOTE

When operating your fire for the first time, some vapours may be given off which may
cause a slight odour and could possibly set off any smoke alarms in the immediate
vicinity. These vapours are quite normal with new appliances. They are totally harmless
and will disappear after a few hours use.

Figure 2.

Содержание Brava 4 Oxysafe

Страница 1: ...gives sufficient details to enable this appliance to be operated and maintained satisfactorily However if further information is required our Baxi Fires Division Technical Helpline will be pleased to help Telephone 08706 061 065 National call rates apply in the United Kingdom In the Republic of Ireland Telephone 0044 8706 061 065 This guide is intended to help you care for your Baxi Fires Division...

Страница 2: ...ils of the proposed use to the following address The Company Secretary Baxi Heating UK Limited Pentagon House Sir Frank Whittle Road Derby DE21 4XA Warning Any person who does any unauthorised act in relation to a copyright work may be liable to criminal prosecution and civil claims for damages Baxi Fires Division Erdington Birmingham B24 9QP www firesandstoves co uk Because our policy is one of c...

Страница 3: ...y the British Standards Institute The Highest Standards Baxi Fires Division is a member of the Society of British Gas Industries which works to ensure high standards of safety quality and performance Careful Installation Baxi Fires Division is a CORGI registered company All our gas fires must be installed by a competent CORGI Registered Installer in accordance with our Installer Guide and should n...

Страница 4: ...ngent quality performance and safety requirements to provide you with many years trouble free service This guide aims to improve your understanding and appreciation of your gas fire by providing simple and informative instructions to ensure that you benefit from the excellent performance and features it has to offer SAFETY Page 4 OWNER GUIDE Baxi Heating U K Limited 2006 IF YOU SMELL GAS DON T SMO...

Страница 5: ...y 25mm of additional shelf depth See graph 1 Please bear this in mind if ever you add a shelf Do provide a suitable guard that complies with BS 8423 for the protection of young children the elderly and the infirm Such a guard is also recommended for the protection of pet animals Although this fire conforms to all the applicable standards it is a heating appliance and certain parts of its surface w...

Страница 6: ...in mind if ever you are considering altering the room Don t hang clothing towels or any other fabrics over the fire Don t fill in the space behind the fascia Don t use the fire without the dress guard being in position Don t attempt to clean or service the fire until it has been switched off and allowed to completely Don t use the fire with damaged radiants APPLIANCE DIMENSIONS Page 6 OWNER GUIDE ...

Страница 7: ...ent any gas flow unless the control knob is held down at the ignition position If for any reason the flames go out when the fire is hot or if the fire is turned off when hot always wait at least three minutes before attempting to relight To light the fire Manual ignition The control is shown in Figure 2 Depress the control knob and turn anticlockwise towards the 1 IGN position A spark should be ge...

Страница 8: ...s will cause resistance to be felt Depress the control knob Sparks should be generated at the pilot The sparks should ignite the pilot If the pilot does not light turn the control knob back to the OFF position and try again The pilot flame can be seen through the opening immediately below the right hand centre radiant See figure 3 If no sparks are generated at the pilot the battery may have no pow...

Страница 9: ...warm up before setting to your preferred heat level For your own convenience have the heater serviced as soon as possible CLEANING YOUR FIRE Turn the fire off and allow it to cool before attempting any cleaning Normally the fire will only need dusting The bright metal trims may be cleaned with a damp cloth and dried with a soft duster Obstinate marks can be removed from the guard and trims using s...

Страница 10: ...taining channel Replace the dress guard To do this locate one side of the dress guard into the two side fixing holes Spring the dress guard slightly and locate into the opposite fixing holes Take care not to scratch the trim MAINTENANCE Battery replacement Electronic ignition 1 The battery cover is located at the base of the fire on the right hand side 2 To access the battery cover the fascia will...

Страница 11: ... fall and accumulate causing the flue to be blocked or restricted and so preventing proper clearance of dangerous exhaust fumes In the United Kingdom it is the law that a landlord must have any gas appliance flue and pipework which is situated in a tenant s premises checked for safety at least every twelve months by a competent person In the U K a CORGI registered installer We recommend that all g...

Страница 12: ...l advice about gas and your gas fire BAXI FIRES DIVISION TECHNICAL HELPLINE 08706 061 065 To report faults or arrange for your fire to be serviced BAXI FIRES DIVISION SERVICE 08706 090 081 For sales or product information BAXI FIRES DIVISION SALES 08706 061 067 For spares inquiries Spare parts are available nationwide via the interpart stockist network For your local stockist consult Yellow pages ...

Отзывы: