Installation Instructions – page 2

Natural Gas

INTRODUCTION

Baxi Boston 2 80 RS

G.C.Nº. 41 077 89

Baxi Boston 2 70 RS

G.C.Nº. 41 077 88

Baxi Boston 2 60 RS

G.C.Nº. 41 077 87

Baxi Boston 2 50 RS

G.C.Nº. 41 077 86

Baxi Boston 2 40 RS

G.C.Nº. 41 077 85

Baxi UK Limited is one of the leading manufacturers of
domestic heating products in the UK.

Our first priority is to give a high quality service to our
customers. Quality is built into every Baxi product -products
which fulfil the demands and needs of customers, offering
choice, efficiency and reliability.

To keep ahead of changing trends, we have made a
commitment to develop new ideas using the latest
technology - with the aim of continuing to make the products
that customers want to buy.

Baxi is also the largest manufacturing partnership in the
country. Everyone who works at the company has a
commitment to quality because, as shareholders, we know
that satisfied customers mean continued success.

We hope you get a satisfactory service from Baxi. If not,
please let us know.

The Boston 2 RS is a range of Floor Standing Room Sealed
Boilers. There is a choice of outputs listed below:

The boilers share a common outer case within which there is
adequate space to fit a central heating pump using standard
fittings. An under work surface top panel is supplied with the
boiler to enable the unit to be fitted under a work top. The
pump cannot be fitted in the case in this type of application
(See PUMP).

All appliances are designed for use on Gas Type G20
(Natural Gas) only, at supply pressure 20 mb.

Each appliance consists essentially of three components,
namely:

1.  COMBUSTION CHAMBER with heat exchanger, burner,
controls and inlet of air duct.

2.  OUTER CASE.

3.  BALANCED FLUE TERMINAL.

“Benchmark” Log Book

As part of the industry-wide “Benchmark” initiative all Baxi
boilers now include an Installation, Commissioning and
Service Record Log Book. Please read the Log Book
carefully and complete all sections relevant to the
appliance and installation. These include sections on the
type of controls employed, flushing the system, burner
operating pressure etc. The details of the Log Book will be
required in the event of any warranty work. Also, there is a
section to be completed at each subsequent regular
service visit.

The boilers listed below meet requirements of Statutory
Instrument ‘The Boiler (Efficiency) Regulations 1993 No
3083’ and therefore are deemed to meet the requirements of
Directive 92/42/EEc on the efficiency requirements for new
hot water boilers fired with liquid or gaseous fuels.

Boston 2 - 80 RS  -  G.C.Nº 

41 07789

Boston 2  -70 RS  -  G.C.Nº

 41 07788

Boston 2 - 60 RS  -  G.C.Nº

 41 077 87

Boston 2 - 50 RS  -  G.C.Nº

 41 07786

Boston 2 - 40 RS  -  G.C.Nº

 41 07785

Type test for the purposes of Regulation 5 certified by:

NOTIFIED BODY 0086

Baxi is a BS-EN ISO 9001
Accredited Company

Product/production certified by:

NOTIFIED BODY 0086

Содержание Boston 2 40 RS

Страница 1: ...Baxi Boston 2 RS Floor Standing Room Sealed Gas Fired Central Heating Boilers Comp No 235322 Iss 5 6 00 Please leave these instructions with the User Installation and Servicing Instructions ...

Страница 2: ...the unit to be fitted under a work top The pump cannot be fitted in the case in this type of application See PUMP All appliances are designed for use on Gas Type G20 Natural Gas only at supply pressure 20 mb Each appliance consists essentially of three components namely 1 COMBUSTION CHAMBER with heat exchanger burner controls and inlet of air duct 2 OUTER CASE 3 BALANCED FLUE TERMINAL Benchmark Lo...

Страница 3: ...nts nationwide When ordering a terminal guard quote the appliance model number The guard manufacturers listed below can be contacted for terminal sizes and guard model numbers VENTILATION Detailed recommendations for air supply are given in BS 5440 2 The room in which the boiler is installed does not require a purpose provided air vent When the boiler is installed in a purpose made cupboard air ve...

Страница 4: ...se copper pipe for the boiler Flow and Return The copper must extend at least 1 metre from the boiler and include any branches The copper pipe must not be insulated GAS SUPPLY The gas connection is located at the bottom left hand side of the appliance and is Rc in B S P T internal Ensure that the pipework from the meter to the appliance is of adequate size Do not use pipes of a smaller size than t...

Страница 5: ...d Pipe sizes are suitable for the system design PUMP Fig 5 A suitable pump e g Grundfos UPS 15 50 15 60 or equivalent Myson or Wilo with ball type isolating valves and 22mm compression fittings may be fitted inside the outer case The pump should be connected to the in flow connection on the front of the heat exchanger using the following standard fittings A 1 off Elbow BSP male x BSP female B 1 of...

Страница 6: ...Fitting the Appliance page 6 ...

Страница 7: ...arrying conductors become taut before the earthing conductor if the cable should slip out of the cable grip 1 With the outer case assembled as in Outer Case 1 4 remove the 2 screws securing the thermostat cover to the facia panel 2 Fit the input cable to the terminal strip and clamp using the cable grip provided and clamp the incoming cable into the cable clips provided on the outer case side pane...

Страница 8: ...inder must be used If a self priming indirect type is employed it must be of adequate size and applied strictly in accordance with the cylinder manufacturers instructions FUEL ECONOMY Better fuel economy is achieved by exercising control of the boiler by means of a room thermostat and or a cylinder thermostat as appropriate ALLOWING THE BOILER TO CYCLE ON THE BOILER THERMOSTAT DOES NOT PRODUCE THE...

Страница 9: ...ght the pilot as previously described Operate the burner and allow the system to reach normal operating temperature Make further checks for leaks and check the burner setting pressure adjusting if necessary This is done by adjusting the throttle screw red plastic surround in either direction as required Fig 7 Remove the pressure gauge and tighten the pressure test point sealing screw The boiler an...

Страница 10: ... c Remove the injector from the feed pipe clean and replace 15 Clean the pilot as follows Unscrew the pilot tubing nuts at both ends and remove the pilot tube Remove and clean the pilot injector and clean the pilot shroud Fig 15 16 Re assemble the pilot components and then the burner in reverse order of dismantling 17 Refit the burner and controls assembly checking that the door seal is undamaged ...

Страница 11: ...Servicing the Unit page 11 ...

Страница 12: ...uple nuts at the valve and at the pilot bracket 3 Disconnect the pilot feed pipe at the valve and at the pilot bracket ensuring that the pilot injector is not misplaced 4 Disconnect the electrode lead and remove the piezo unit 5 Remove the screw securing the electrical terminal cover to the gas valve Disconnect the electrical connections 6 Remove the valve complete with the heat shield and inlet p...

Страница 13: ...Changing Components page 13 ...

Страница 14: ...Short Parts List page 14 Click here for Helplines ...

Отзывы: