4
Important initial information for the Technician
1.1
Safety
The boiler and related accessories reflect the state of the art and meet all applicable safety regulations.
1.2
Please note!
Your boiler and all accessories operate using 230 VAC electrical current. Improper installation or repair can pose
the danger of life-threatening electrical shock. Installation and repair may be performed only by appropriately
qualified technicians.
Caution symbols
Please take careful note of the following symbols in these Installation instructions.
Ignoring the identified warnings can lead to
personal injury
.
Ignoring the identified warnings can lead to
malfunction of, or damage to the boiler or heating sys-
tem
.
The specified safety requirements are to be followed in accordance with nationally applicable regula-
tions, standards and guidelines.
1.3
Fuel
The boilers are designed to burn the following fuels:
Pellets according to ÖNORM M7135 or DIN
plus.
Significant criteria based on the standards are as follows:
Diameter 6 mm
Length 80% between 15 – 30 mm
Smooth surface
Density at least 1.1 kg/dm3
Residual moisture content max. 10%
Energy content min. 18 MJ/kg = 5 kWh/kg
(in water-free condition)
Ash content max. 0.5%
Abraded particles max. 2.3%
Chemical/synthetic binding agents are strictly prohibited No impurities from varnish or paint residues, etc.