![Baxi Bioflo Скачать руководство пользователя страница 44](http://html.mh-extra.com/html/baxi/bioflo/bioflo_installation-and-servicing-instructions-manual_2711687044.webp)
43
For the Service Technician
4.5.2 Start-up
The auger conveyor and the feed can be selected on the Start-up level with the
arrow buttons and the selec-
tion confirmed with the
Choose button. A self-test is started at the end of the start-up.
Auger conveyor
The auger conveyor can be switched on for 6 minutes.
Feed
Depending on the set feed system, the feed and each probe including pur-
ging can be started up.
Fig. 72
Start-up
Auger conveyor
Feed
Choose
Back
Fig. 73
Fig. 74
4.5.3 Actuator test
The following actuators can be selected with the
arrow buttons, then confirmed and started using the Choose
button. The actuators are switched off again after 1 minute. A self-test is started at the end of an actuator test.
–
Induced draught fan
–
Auger conveyor
–
Ash removal
–
Ignition element
–
Ash compression
–
Suction turbine
–
Probe switching
–
Boiler pump
Induces draught fan
Auger conveyor
Ash removal
Ignition element
Ash compression
Suction turbine
Choose
Back
Probe switching
Boiler pump
Choose
Back
4.5.4 Installation of MES modules
Display when an MES module is installed (connected) or uninstalled (discon-
nected) – Fig. 75.
Fig. 75
Installation procedure
active
.....
(Animated symbol)
Содержание Bioflo