Supplied By www.heating spares.co Tel. 0161 620 6677
page 15
Propane Cat ll
2H3P
Supplementary Instructions
BERMUDA GF3 SUPER PROPANE
G.C.N
o
37 077 69
GAS TYPE G31
This section details the differences between Natural
Gas and Propane models.
Propane firefronts are only suitable for use with
Bermuda 553 Propane Back Boiler appliances. The
instructions supplied with the back boiler contain details
of gas supply requirements and electrical connections.
All site requirements and installation details can be
found earlier in this booklet.
NOTE: When removing the burner it is necessary to
remove the right hand retaining screw and the left
hand coal bed retaining pin which also retains the
burner.
Bermuda GF3 Super Propane
5.64kW (19,243 Btu/h)
G31 (Propane)
P 100
37.0mbar
14.8in wg
35.0 + 1.7mbar
14.0 + 0.7in wg
Heat Input (Gross)
Gas Group
Injector Marking
Supply Pressure
Setting Pressure (Cold)
The following spares components differ from Natural Gas
models.
Description
G.C.N
o
Manufact'rs
Part N
o
Flame Failure Device/Gas Tap
Concentric TE/SA 2632
E01-143
237100
Injector - Fire Propane - P 100
378 856
092089
Burner - Aeromatic - Propane
E01-145
237209
A.S.D. Assembly
E01-152
237810
Coal Bed - Propane
E01-144
237221
Pin Coal Bed Locating/Burner Securing
156 097
092125
Bermuda GF3 Super Propane
Propane appliances can be converted to operate on
Natural Gas if required.
A conversion kit is available, Baxi Part No 247064.