It is important that the existing installation is correct and
that the flue is performing satisfactorily. Any remedial
work necessary should be completed before the new
appliance is commissioned. Please read the Important
Information Section on page 4.
WARNING: When a renewal firefront is installed with a
Bermuda 401, 552, 45/3 or 57/3 which does not have
an Atmospheric Sensing Device fitted the combined
appliance will not shut down under adverse flue
conditions. (When the fire is used without the boiler
on, the Atmospheric Sensing Device will operate).
NOTE:
A permanent live is required for correct operation
of the firefront.
Boiler Modification
Additional Installation Instructions
Bermuda GF3 Super Renewal
G.C.N
o
37 075 01A
Bermuda LFE5 Super Renewal G.C.N
o
37 075 03A
The kit supplied with Renewal appliances provides all the
necessary components to fit a Baxi Bermuda GF3 Super
Renewal & Baxi Bermuda LFE5 Super Renewal firefront
to the following Bermuda Boilers.
The Renewal Fires may be used with the following
Boilers:
Bermuda 401
G.C.N
o
44 077 49
Bermuda 552
G.C.N
o
44 077 50
Bermuda 45/3 M
G.C.N
o
44 077 61
Bermuda 45/3 E
G.C.N
o
44 077 60
Bermuda 57/3 M
G.C.N
o
44 077 63
Bermuda 57/3 E
G.C.N
o
44 077 62
Bermuda 45/4 M
G.C.N
o
44 077 71
Bermuda 45/4 E
G.C.N
o
44 077 73
Bermuda 57/4 M
G.C.N
o
44 077 72
Bermuda 57/4 E
G.C.N
o
44 077 74
Bermuda 51/5
G.C.N
o
44 075 06
Existing Fire
REMOVING THE EXISTING FIRE
Isolate the gas and electrical supply, including any
permanent live, to the combined appliance.
Remove the controls cover panel from the front of the fire.
Remove the tap control knob. Disconnect the electrical
socket from the fire plug if fitted. Remove the screws
securing the outercase to the innercase. Lift off the
outercase.
Turn the gas service tap to the "Boiler only" position by
turning
1
/
4
turn clockwise.
Remove the radiants if fitted.
Disconnect the supply pipe at the fire inlet.
Remove any screws securing the fire to the wall. Pull the
fire forward until the flue spigot is clear of the boiler hood
and lift away.
Remove and discard the fire supply pipe from the service
gas tap. Disconnect and discard any electrical wiring
between the boiler input terminal and the fire.
Adhesive Foil Label
Renewal Firefront
NOTE: It is important at this stage to fit the
controls heat shield supplied with the fire unit to
the boiler front panel.
Remove and discard the controls heat shield
provided with the boiler and fit the new controls heat
shield using the screws previously removed.
Check the data badge on the back boiler. If the boiler
internal wiring is not depicted, take the foil label from
the kit and attach it below the data badge on the
boiler front door.
If a radiant firefront has been installed previously it
will be necessary to unscrew and remove the
extension plate from the boiler controls heat shield.
Once removed this item can be discarded.
BERMUDA 45/3 & 57/3, 45/4, 57/4 & 51/5
BERMUDA 401 & 552
New Controls
Heat Shield
Controls Heat
Shield
Extension Plate
Bermuda 57/3 Illustrated