2.
After checking, turn off the appliance. Remove the pressure gauge and replace the test point sealing screw.
3.
Relight the appliance. Turn to the maximum output position and test around the sealing screw for gas
soundness with a suitable leak detection fluid.
Page 15
8. FITTING THE FIREFRONT
8.1 For models NOT supplied with a firefront.
A slotted firefront with a minimum free area as shown in figure 8 must always be used.
8.2 For models SUPPLIED with a firefront.
The firefront supplied with this fire has been tested and found to be satisfactory for use with this fire. The open
area may differ slightly from that shown in
figure 8
.
Figure 8. Firefront minimum open area requirements
Place the decorative firefront on the hearth and central to the appliance.
Page 16
9. CERAMIC COALS INSTALLATION
The ceramic fuel effect may cause staining / discolouration to decorative surfaces. It is therefore advisable to
protest decorative surfaces.
1.
Place the ceramic base coal in the burner compartment. The bottom rear face of the coal should rest on the
angled ledge at the back of the burner tray. The bottom front recess of the coal base should locate against the
tags at the front of the ceramic support (See
figure 9
).
Page 14 of 25