16.5 To replace the control slide unit.
1.
Remove the fascia (See section 16.4).
2.
Detach the slide unit by removing two screws
securing the plastic slide mechanism to the rear of the
fascia (See figure 33).
3.
Replace in the reverse order.
16.6 To replace the control slide button.
1.
Remove the fascia (See section 16.4).
2.
Remove the control slide unit (See section 16.5)
3.
Detach the slide button by removing two screws.
4.
Replace in the reverse order.
16.7 To remove the burner unit.
1.
Remove the fire front and fascia - See section
16.4.
2.
Remove the loose ceramic fuel effect pieces, the front ceramic
fuel effect and the base ceramic fuel effect.
3.
Close the isolating valve in the inlet ‘T’ connector. Support the
inlet ‘T’ connector to avoid straining the pipework and disconnect
the appliance from the ‘T’ connector.
4.
Detach the burner unit from the convection box by removing two
screws (See figure 34).
5.
Replace in the reverse order.
Page 33
©
Baxi Heating U.K. Limited 2010.
Figure 34. Burner attachment points
Figure 33.
Control slider
Figure 32. Control linkage
disconnection