The stove body contains the following:
1 Burner module.
1 Inlet ‘T’ connector with nut and olive.
1 Vent switch and mounting bracket assembly.
1 Diverter box.
1 Down draught deflector.
1 Control knob assembly.
4. STOVE SET UP
Legs and lower casting cover (See figure 1).
Locate the four leg securing studs into
the four holes in the base of the body.
Locate the four legs to the underside
of the casting body. There are two feet
with holes in the base. We recommend
that these be placed at the rear of the
stove.
Place the front cover casting on top of
the front legs.
Secure the legs and front cover casting
to the underside of the casting body using
the nuts and washers supplied.
Flue collar, diverter box, flue spigot and flue restrictor plate.
These should be located to the stove as in figure 2. Do not bolt in place until fitting
the deflector. The flue restrictor is for use where the flue draught is excessive. The
flue spigot is screwed to the cast flue collar and clamps the flue restrictor plate in
place (See figure 2).
There may however, be certain circumstances where fitting the restrictor causes the
fire to fail the spillage test. In such cases the restrictor will have to be removed. After
removal conduct the spillage check again.
Page 8
©
Baxi Heating U.K. Limited 2010.
Figure 1.