background image

OPERATING YOUR STOVE

This stove is supplied with ceramic fuel effect to simulate a real stove. After some
use, these may change colour. This is quite normal.

The Flame Sensing & Flue Blockage Safety System.

For your safety, this appliance is fitted with a flue blockage safety device that will shut
down the appliance in the event of abnormal flue conditions. 

This device is NOT a

substitute for an independently mounted Carbon Monoxide detector

The device will also automatically shut off the gas supply to the gas stove if the pilot
flame goes out for any reason. 

If the device starts to shut off the gas frequently,

get expert advice.

The system incorporates a probe that senses that the heat from the pilot flame is
correct. If this probe is cool, the device will prevent any gas flow unless the control
knob is kept depressed at the PILOT/IGN position. 
If the safety system operates and the flames go out 

wait at least ten minutes before

attempting to relight

.

Always make sure that the door is securely closed before lighting.

If the gas valve is operated to turn the stove off always 

wait at least three minutes

before attempting to relight

.

Always make sure that the door is securely closed before lighting.

Lighting the burner.

 

Depress the control knob and rotate it anticlockwise to the pilot ignition position

(See figure 2). A 'click' will be heard as
the integral piezo operates. A flame
should appear at the pilot. Keep the
control knob depressed and hold the
pilot ignition position for five seconds.
When the control knob is released the
pilot flame should remain lit. If a flame
does not appear at the pilot then turn
the control knob clockwise to the 'OFF'
position and repeat the above.

Page 23

© 

Baxi Heating U.K. Limited 2010.

PLEASE NOTE

When operating your stove for the first time, some vapours may be given off which may
cause a slight odour and could possibly set off any smoke alarms in the immediate
vicinity. These vapours are quite normal with new appliances. They are totally harmless
and will disappear after approximately twelve hours use.

OWNER GUIDE

Figure 2.

Содержание 910

Страница 1: ... Model 910 CAST IRON GAS STOVE Fitted with a Ceramic Coal fuel effect GC No 32 264 24 INSTALLER AND OWNER GUIDE For further advice please contact the retailer or company from where you purchased your fire INSTALLER Please leave this guide with the owner ...

Страница 2: ...ls of the proposed use to the following address The Company Secretary Baxi Heating UK Limited The Wyvern Business Park Stanier Way Derby DE21 6BF Warning Any person who does any unauthorised act in relation to a copyright work may be liable to criminal prosecution and civil claims for damages Because our policy is one of constant development and improvement details may vary slightly from those giv...

Страница 3: ...Page 3 INSTALLER GUIDE Baxi Heating U K Limited 2010 INSTALLER GUIDE FOR OWNER GUIDE SEE PAGES 19 TO 25 ...

Страница 4: ...witch 10 Diverter box 10 5 GENERAL INSTALLATION REQUIREMENTS 11 Regulations Standards and Law 11 The Hearth 11 Clearances 12 Flue Chimney 12 Ventilation 13 Location 13 Propane gas 13 Gas connection 13 Securing the stove 13 Fitting the ceramic fuel effect 14 6 OPERATING THE STOVE 14 Pre lighting checks 14 Lighting the burner 14 Operating the burner 14 Inlet pressure check 15 Check for spillage 15 F...

Страница 5: ... from asbestos or asbestos related products Installer Firefox stoves are efficient appliances giving off convected conducted and radiated heat All the surfaces of the stove except the controls are working surfaces and become hot in use They must not be touched or have any combustible objects or materials placed on or near them A fire guard complying with BS 8423 should be fitted for the protection...

Страница 6: ...cy of this appliance has been measured as specified in BS EN 613 and the result is as below Model Efficiency Gross 910 73 1 910 when converted to LPG 73 1 Page 6 Baxi Heating U K Limited 2010 Gas Natural G20 Propane G31 Inlet Pressure 20mbar 37mbar Input Max Gross 5 50kW 18 766Btu h 5 4kW 18 425Btu h Input Min Gross 2 3kW 7 850 Btu h 3 8kW 12 965Btu h Inlet Test Pressure Cold 20 0 1 0mbar 8 0 0 4i...

Страница 7: ...Lower casting cover 4 Threaded studs For feet lower casting cover 4 securing nuts For feet lower casting cover 4 flat washers For feet lower casting cover 4 locking washers For feet lower casting cover 2 wall plugs For securing feet to floor 2 wood screws For securing feet to floor 1 Small nut and bolt For vent switch 2 bolts with washers For the diverter box 3 self tapping screws For burner 1 Flu...

Страница 8: ... front legs Secure the legs and front cover casting to the underside of the casting body using the nuts and washers supplied Flue collar diverter box flue spigot and flue restrictor plate These should be located to the stove as in figure 2 Do not bolt in place until fitting the deflector The flue restrictor is for use where the flue draught is excessive The flue spigot is screwed to the cast flue ...

Страница 9: ... washer from inside the top of the casting body Position the down draught deflector as in figure 3 It MUST be sealed against the top of the stove casting It is important that it sits on top and between the raised cast areas on the rear of the stove body See figure 3 Secure in place using the nut and washer removed previously Page 9 Baxi Heating U K Limited 2010 Figure 2 INSTALLER GUIDE Figure 3 ...

Страница 10: ... using the bolts and washers supplied Burner module Offer the burner module into the stove and connect the thermal switch leads to the tags mid way along the thermocouple Locate the burner assembly inside the stove body as in figure 5 The outer front of the stove is not shown for clarity The rear leg of the burner should sit on the rear of the casting Secure using the three screws supplied The scr...

Страница 11: ...sh Office In Scotland the current edition of the Building Standards Scotland Regulations issued by the Scottish Executive In Northern Ireland the current edition of the Building regulations Northern Ireland issued by the Department of the Environment for Northern Ireland In the republic of Ireland the installation must be carried out by a competent person and also conform to the relevant parts of ...

Страница 12: ...r sleeve will require reducing in length so that it protrudes 25mm below the outer sleeve See figure 7 Before you install the stove make sure the chimney flue outlet is correctly positioned to align with the flue outlet on the stove and that the chimney is in good condition If not a chimney liner must be installed or a suitable class 2 gas flue used A draught is necessary to ensure the products of...

Страница 13: ...to affect the appliance the appliance must not be installed unless the fan is permanently disconnected Location This appliance must not be installed in a private garage or any room which contains a bath or shower or where steam is regularly present Propane gas Propane gas appliances must not be installed in a cellar basement or other room which is built entirely below ground level See Gas Safety I...

Страница 14: ...ob clockwise to the Off position Repeat this operation until a flame appears at the pilot The pilot can be seen by looking through the space in the left hand front of the fuel effect See figure 8 There may be a delay before the pilot lights due to air being purged from the system When a flame appears at the pilot keep the control knob depressed and hold the pilot ignition position for five seconds...

Страница 15: ...y Do not use a lighted match or a naked flame If the smoke is not drawn into the appliance leave the appliance alight at the maximum setting for a further ten minutes and then repeat the test If the flue restrictor is fitted then remove the restrictor and repeat the above test If the smoke is still not drawn into the appliance then disconnect the appliance and seek expert advice If the above test ...

Страница 16: ...e goes out for any reason wait at least ten minutes before relighting Stress that if the monitoring system repeatedly shuts off the stove the appliance should be switched off and a specialist should be consulted Advise the customer that they should read their owner guide before operating the stove and always follow the advice in the section headed Cleaning your stove Stress that no extra ceramic f...

Страница 17: ...hen replacing these articles we recommend that the replaced items are not broken up but are sealed within a heavy duty polythene bag clearly labelled as RCF waste RCF waste is classed as a stable non reactive hazardous waste and may be disposed at a landfill licensed to accept such waste Protective clothing is not required when handling these articles but we recommend you follow the normal hygiene...

Страница 18: ... ensure that the aeration setting is correct Check the aeration shutter setting See figure 10 To adjust the aeration setting loosen the two aeration shutter screws slide the aeration shutter to the position shown in figure 10 and tighten the fixing screws Page 18 Baxi Heating U K Limited 2010 INSTALLER GUIDE Figure 10 Aeration shutter setting ...

Страница 19: ...Page 19 Baxi Heating U K Limited 2010 OWNER GUIDE OWNER GUIDE ...

Страница 20: ...AINTENANCE AND SERVICING 26 Regular maintenance 26 Servicing 26 This appliance has been designed to meet the most stringent quality performance and safety requirements to provide our customers with many years trouble free service Your owner guide aims to improve your understanding and appreciation of your gas stove by providing simple and informative instructions to ensure that you benefit from th...

Страница 21: ...unt must the stove stand on carpets or other combustible materials The stove must stand on a non combustible hearth surface The hearth material must be at least 12mm 1 2 thick and should protrude at least 150mm 6 in front of the stove body Do provide the minimum clearances shown in figure 1 Page 21 Baxi Heating U K Limited 2010 Figure 1 Dimensions and Clearances IF YOU SMELL GAS DON T SMOKE EXTING...

Страница 22: ...stove with the door open or with the glass panel damaged or removed The door should always be secured with the locking screw See Cleaning your stove If the window is damaged or will not close securely the stove must be turned off and not used until the window is changed or corrected by a competent service engineer Don t hang clothing towels or any other fabrics over the gas stove Don t put more lo...

Страница 23: ...e attempting to relight Always make sure that the door is securely closed before lighting If the gas valve is operated to turn the stove off always wait at least three minutes before attempting to relight Always make sure that the door is securely closed before lighting Lighting the burner Depress the control knob and rotate it anticlockwise to the pilot ignition position See figure 2 A click will...

Страница 24: ...e flames will appear predominantly blue The fuel effect pieces will take time to warm up Although some glow will be seen after approximately ten minutes the full visual effect will only be apparent after a somewhat longer time iii The appliance will operate to its maximum potential if the flue is primed during the first 20 30 minutes of operation To do this simply slide the control button to its h...

Страница 25: ... prevent inadvertent opening and consequent injury or damage while the stove is in use To lock the door turn the locking bolt clockwise until it reaches its stop point The Glass Window Any stains on the glass can be removed with a non abrasive cleaner such as a ceramic hob cleaner Never use abrasive cleaners Clean the window carefully in accordance with the instructions supplied with the cleaner F...

Страница 26: ...SAFE REGISTER engineer We recommend that all gas appliances and their flues wherever situated are checked annually Servicing To help us quickly help you please try to have the following information available before you contact us Type of stove Gas Model Name Serial Number You will also be asked for the fault problem or request plus your Post Code If you wish to replace any of the ceramic fuel effe...

Страница 27: ... Baxi Heating U K Limited 2010 ...

Страница 28: ... Baxi Heating U K Limited 2010 ...

Отзывы: