10.2.2
Operating the burner.
1.
When the burner is operating properly, gradually lift the control pivot plate upwards.
The burner flames should gradually increase until the control pivot plate is nearly at its
highest position. You should feel some resistance when the control pivot plate reaches
the maximum burner flame position. Lifting further upwards until the control pivot
plate comes to a stop should then turn the burner and pilot off. When the above checks
have been completed close the isolating valve on the inlet ‘T’ connector. If the above
checks are satisfactory, continue with the installation. If not, check the control and
ignition circuitry and components as described in the servicing section of this manual.
10.3 Inlet pressure check.
The appliance is pre-set to give the correct heat
input at the inlet pressure shown in section 2 of this
manual. No adjustment is necessary.
1.
Check the inlet pressure by fitting a pressure
gauge at the test point. The test point is on the inlet
‘T’ connector (See figure 19). Check the pressure
with the appliance alight and set at maximum
output.
2.
After checking, turn off the appliance. Remove
the pressure gauge and replace the test point sealing
screw.
3.
Relight the appliance. Turn to the maximum
output position and test around the sealing
screw for gas soundness with a suitable leak
detection fluid.
10.4 Fitting the burner tray trim to the
Chic model.
The ‘Luxor’, ‘Opulent’, ‘Envy’, ‘Heritage’
and ‘Westminster’ models do not have a
burner tray trim.
1.
Fit the burner tray trim over the front rim of
the burner tray. There are two tags which
locate over the edge of the burner tray. Push
the trim fully down (See figure 20).
Page 25
INSTALLER GUIDE
©
Baxi Heating U.K. Limited 2006.
Figure 20. Fitting burner tray trim
to ‘Chic’ model.
Figure 19. Pressure test point