background image

Baxi 11i

Baxi 14i

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Содержание 11i

Страница 1: ...Baxi 11i Baxi 14i INSTALLATION OPERATION AND MAINTENANCE MANUAL ...

Страница 2: ......

Страница 3: ...d on the product indicates that it conforms to the following European Directives 142 2009 93 68 0694 0694CP4791 INDEX GENERAL SAFETY pag 4 1 TECHNICAL CHARACTERISTICS pag 4 1 a Technical Data pag 4 2 INSTALLATION pag 6 2 a Regulations pag 6 2 b Mounting to wall pag 6 2 c Room ventilation pag 6 2 d Electrical connection to battery pag 6 2 e Gas Connection pag 7 2 f Water connection pag 7 2 g Dispos...

Страница 4: ...terials If a gas leak is detected do not switch on any electrical de vices telephones or any other objects that could produce a spark Ventilate the area by opening the doors and windows and switch off the gas supply Do not place objects on top of the device Do not leave flammable containers or substances in the area where the device is installed Do not attempt to repair the machine if it breaks do...

Страница 5: ...Temperature regulator 8 Gas valve 9 Gas input 10 Gas adjustment screws 11 Electronic devices 12 Battery box 13 Economiser 14 Gas pressure intake 15 Pilot burner 16 Sensor Fig 1 Misure in mm A B Ø C D E F G H 11i 592 110 101 245 314 97 54 25 14i 650 130 101 245 365 117 74 45 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Fig 2 ...

Страница 6: ...or fan fireplaces and other simi lar devices at the same time as the water heater The area where the water heater is installed must have a regular flow of air for ventilation Air flow The flow of air must occur by the following means Permanent openings in the wall that lead outdoors Single or collective ventilation ducts The air used for ventilation must be taken directly from an outside location ...

Страница 7: ...iser 20 Gas valve 21 Safety device 22 Gas filter 23 Battery 24 Electrical card 25 Microswitch 26 Sensor Fig 6 2 g Disposal of waste product This B11BS water heater is supplied with a device for releasing flue gas For output of combustion by products refer to the regulations in force including any updates See paragraph 2 a The gas devices with an attachment for a waste gas flue must be connected di...

Страница 8: ...ring taking care with the di rection of the insertion fig 16 and making sure that the drilled spring guide disc is in its correct position fig 15 Remount the diffuser attaching it to the upper hole Remount the pilot flame IV DISABLING THE GAS ADJUSTER Remove the protective cap Regulate the supply calibration screws so that the maximum amount of gas can pass disk completely horizontal After regulat...

Страница 9: ...f the burner automatically switches off the device then awaits another heating request If after 60 seconds it does not switch on the flame detector inter rupts the flow of gas and blocks the device To reuse the device after it has been blocked close the hot water extraction tap and then reopen it to restart the sequence If the main burner accidentally switches off the device will attempt to turn i...

Страница 10: ...broken Test substitute There isn t sufficient water pressure Repair the device to guarantee pressure rotate the selector knob all the way to the right The membrane is broken Substitute The electrode is damaged Substitute The pilot does not switch on when there is a spark Safety device broken Substitute No gas supply Open the gas tap Air in the gas tubes Release gas The burner does not switch off w...

Страница 11: ... G30 G31 28 30 37 mbar Baxi 11i Pn 19 0 kW Qn 21 8 kW Pm 7 5 kW Qm 9 0 kW P H2O max 10 0 bar B11BS Made in IR 1 5 V Pn Nominal power usage Qn Nominal thermal range Pm Minimal power usage Qm Minimal thermal range P H2 O max Maximum water pressure Category Nominal feed pressure Appliance type Voltage ...

Страница 12: ......

Отзывы: