![Baxi Fires Division Anthem BR660VA Скачать руководство пользователя страница 23](http://html.mh-extra.com/html/baxi-fires-division/anthem-br660va/anthem-br660va_installers-manual_2712152023.webp)
shown below in figure 18.
Note : Use aluminium tape provided to
seal adjoining edges of the jacket as
shown, unless cable fixing method is to
be used, in which case, tape up after
cables are in position.
Now connect the wiring loom at the
firebox end, the eight pin connector is
located on the lower left hand side of the
appliance. Take two ‘P’ clips from the
loose parts bag, and use them to secure
the loom to the upper left hand side of
the firebox. Two fixing holes can be
found in this area of the firebox.
Use the fixing screws provided and now
secure the ‘P’ clips and the loom over the top of the insulation jacket ensuring that
approximately 250mm of slack exists between the eight pin connector and the first ‘P’
clip.
This slack is necessary to allow removal of the electrical control unit in future
servicing.
Obtain the previously prepared flue tube and attach to the spigot on the back of the
firebox.
Ensure that the flue pipe is not fitted in reverse. i.e. The stepped end is the firebox
end.
Now offer the complete assembly as a unit to the wall.
Take care not to damage the wiring loom as the flue pipe is inserted through the wall.
Now it is necessary to secure the firebox to the wall.
8.1 Securing firebox to wall - cable retention.
1.
Assemble retention cables into firebox.
2.
Insert cables into cable anchor points in upper rear of firebox and then tape together
adjoining edges of the jacket as shown in figure 18.
3.
Offer the firebox up to the wall and feed the retention cable through the installed
eyebolts.
4.
Return the cables through the holes provided at the lower back of the firebox.
5.
Assemble adjusters and tension as in figure 19
.
Page 23
INSTALLER GUIDE
Figure 18.