USING THE HEATER

Important Safety

Never cover the heater or obstruct the openings at the base of the heater, this could
cause overheating and consequent risk of fire.

What are the three switches for?

The heater is operated by three switches located below the hood on the left hand side of
the heater.

Switch 1   = 

O

Main On - Off

In the On position only the fuel effect operates

Switch 2   =    

I

1kW fan heat setting and fuel effect

Switch 3   =   

II

2kW fan heat setting and fuel effect

The switches are connected on the inside, so when switch 1 is turned off, all switches 
turn off.

CLEANING AND MAINTAINING THE HEATER

How do I clean my heater?

The heater fascia and glass parts need only to be wiped clean with a dry soft cloth, do
not use polishes or abrasive materials. The Adage and Anthem heaters may have finger
prints on the fascia surface. These can be removed by applying a small amount of ‘baby
oil’ to a lint free non-abrasive cloth and wiping the surface. Use a clean cloth to remove
the oil.

I have a problem with my heater!

Important Safety 

Before undertaking maintenance or replacing the light bulb(s) always disconnect
the heater from the electricity supply by removing the 3 pin plug and allowing the
heater to cool completely.

1. My heater is on but there is no light or the light appears brighter on one
side of the heater.

This is possibly a light bulb failure.  Remove the light bulb(s) as follows and check it /
them in a table lamp that is known to work. If it / they do not work in the table lamp

Page 16

INSTALLER AND OWNER GUIDE

© 

Baxi Heating U.K. Limited 2005.

Содержание 827

Страница 1: ...ision Technical Helpline will be pleased to help Telephone 08706 061 065 National call rates apply in the United Kingdom In the Republic of Ireland telephone 0044 8706 061 065 Important Please keep your guide in a safe place for future reference Baxi Heating U K Limited 2005 Model 827 Electric Heater Fitted with one of the following fascia Adage Anthem Bolero Decadent Dream Eternal Fusion Minima O...

Страница 2: ...on to reproduce any part of this publication should be made giving details of the proposed use to the following address The Company Secretary Baxi Heating UK Limited Pentagon House Sir Frank Whittle Road Derby DE21 4XA Warning Any person who does any unauthorised act in relation to a copyright work may be liable to criminal prosecution and civil claims for damages Baxi Fires Division Erdington Bir...

Страница 3: ...rmance and safety requirements to provide our customers with many years of trouble free service This guide aims to improve your understanding and appreciation of your new heater by providing simple and informative instructions to enable you to install it and to ensure that you benefit from the excellent performance and features it has to offer If you require further assistance the Baxi Fires Divis...

Страница 4: ...3 Minima 6 8 1 16 2 3 Obsession 6 8 1 28 2 3 Style 6 8 4 2 2 3 Victorian 6 8 5 56 2 3 Westminster 6 8 9 56 2 3 A Spacer is supplied with all of the above heaters except the Dream and Bolero models A spacer frame is not available for these models One person should be sufficient to lift the heater If for any reason this weight is considered too heavy then obtain assistance When lifting always keep y...

Страница 5: ... or use the heater anywhere where water is in use i e Bathrooms Kitchens Shower Rooms Swimming Pools etc Never use aerosols or steam cleaners on or around the heater Never route the electric supply cable under carpet etc Never install the heater close to curtains or combustible materials Never use the heater to dry clothes etc Never sit or stand on the heater FITTING THE HEATER The installation of...

Страница 6: ... be used against flat walls unless fitted to a rebated surround or suite Important electrical safety The heater must not be located in front of or under an electrical socket the socket must always be accessible in order to disconnect the heater from the electrical supply for maintenance and cleaning Important This heater must be earthed The heater is supplied with a 3 pin 13 Amp fused re wireable ...

Страница 7: ... the cable guide into the required rectangular slot 2 Place the electrical cable into the guide and close the top of the cable guide If the electric cable is damaged to avoid a hazard it must be replaced by a Baxi Fires Division authorised service agent or similarly qualified person See the last page of this guide for useful telephone numbers All external wiring between the heater and the electric...

Страница 8: ...lus Anthem Minima and Style heaters supplied with a three piece fascia The fascia is supplied in separate packaging within the main box Heater fixing All fixings supplied with the heater have been identified in figure 4 Page 8 INSTALLER AND OWNER GUIDE Baxi Heating U K Limited 2005 Figure 3 Removal of Adage and Fusion fascia Figure 2 Removing Decadent Eternal Obsession and Victorian fascia Fascia ...

Страница 9: ...Make sure that the heater is in the middle of the surround or fireplace 2 There are two slotted holes in the top of the heater See figure 5 Mark through the slotted holes so that their position is clear when the heater is removed 3 Remove the heater 4 Drill an appropriate size hole in each of the marked positions Insert wall plugs into the drilled holes 5 Place the heater so that the slotted holes...

Страница 10: ... a small loop of wire at the front of the heater See figure 7 item 3 9 At the back of the heater there will be a long piece and a short piece of wire coming through the two holes Hold the short piece and give the long piece a gentle tug This will secure the steel wire Take the long piece and thread this through the eyescrew in the back of the fireplace opening See figure 7 item 4 10 From the back ...

Страница 11: ...om the fireplace and place away from the work area 5 Drill the screw locations using a no 12 masonry drill bit 6 Insert two wall plugs provided into the holes 7 Insert an A screw into each hole and screw in until there is approximately 6mm of screw protruding from the wall Preparing the heater for installation 1 Ensure that the decorative front surround has been removed from the heater as describe...

Страница 12: ...it It simply drops into the shaped slot in front of the light bulbs See figure 11 Remove any protective film before use Fitting the Fascia Important notes 1 The coal pieces supplied are a natural material Occasionally it will be necessary to reduce the size of the coal pieces To do this place them inside a plastic bag place on a suitable hard surface and tap gently with a small hammer or similar t...

Страница 13: ...e heater See figure 14 2 Secure with the two screws removed previously On the Westminster model the two C screws are in the loose parts pack 3 Fit the firefronts as below Decadent Eternal Obsession and Victorian models The rear of the firefront has two screws that locate into keyhole brackets on the heater See figure 15 On Victorian models screw the brass firefront columns supplied with the firefr...

Страница 14: ...g the Anthem Minima and Style fascia For fascia supplied as three separate parts The Anthem Minima and Style fascia consist of three parts Two sides and a top These are held in place with four magnets 1 Lay the three fascia parts face down on a flat surface as in figure 15 Each side trim has a small tab at the top Position the tab to the outside upper edge See figure 16 2 Locate the left hand side...

Страница 15: ...bbles coals supplied Fitting the one piece Anthem Minima and Style fascia 1 Removing the fascia may have moved the magnets used to fix the fascia to the heater The magnets should be located as in figure 13 2 Locate the fascia onto the heater Ensure that the sides of the fascia sit on the floor hearth Style model The rear of the firefront has two brackets that locate into slotted brackets on the he...

Страница 16: ...e wiped clean with a dry soft cloth do not use polishes or abrasive materials The Adage and Anthem heaters may have finger prints on the fascia surface These can be removed by applying a small amount of baby oil to a lint free non abrasive cloth and wiping the surface Use a clean cloth to remove the oil I have a problem with my heater Important Safety Before undertaking maintenance or replacing th...

Страница 17: ...or plate See figure 11 4 Replace the light bulb with a clear 40 Watt maximum candle Edison screw SES E14 5 Refit the copper reflector plate Refit the firefront fascia and refit the coals pebbles 2 My heater is on but there is no light or heat The first thing to do is check the wall socket To do this plug in a known working appliance If the appliance you have plugged in works then there is a good c...

Страница 18: ...ion available This will help us to deal with your call quicker and avoid you having to make a second call Your Post Code Type of Heater Electric or gas Model Name and serial number This information can be found on a small label attached to the inside lower left of the heater To see this you will have to remove the firefront On the Adage and Fusion heaters it will be necessary to remove the whole f...