9.3
m
Main circuit
m
Terminals and wiring of main circuit
m
DC capacity of main circuit
m
Resistor of main circuit
Check items
Methods and criterion
Maintenance period
Daily
Half
year
One
year
If there are any loose or missing screws
Tighten or replace the screw
O
If machine or insulator is deformed, cracked,
damaged or with changed color change due
to overheating or ageing
Visual inspection
NOTE:
Please ignore the color change of copper plate
O
If there is any dust or dirt
Visual inspection
O
Check items
Methods and criterion
Maintenance period
Daily
Half
year
One
year
If the wiring shows change of color change
or deformation due to overheat
Visual inspection
O
If the insulation of wiring is damaged or the
color has changed
Visual inspection
O
If there is any damage
Visual inspection
O
Check items
Methods and criterion
Maintenance period
Daily
Half
year
One
year
If there is any leakage of liquid, change of
color, cracks or deformation
Visual inspection
O
Measure static capacity when required
Static capacity
≥
initial value X 0.85
O
Check items
Methods and criterion
Maintenance period
Daily
Half
year
One
year
If there is any peculiar smell or insulator
cracks due to overheating
Visual inspection, smell
O
If there is any disconnection
Visual inspection or measure with multimeter after
removing wiring b1/+2 ~ -
Resistor value should be within
±
10%
O
Содержание b maXX BM1000
Страница 1: ...E 5 07003 04 Manual b maXX BM1000 Basic unit ...
Страница 8: ...Manual b maXX BM1000 Document No 5 07003 04 Baumüller Nürnberg GmbH 8 of 174 Table of contents ...
Страница 42: ...Mounting instructions Manual b maXX BM1000 Document No 5 07003 04 Baumüller Nürnberg GmbH 42 of 174 5 6 ...
Страница 100: ...Affecting other machines Manual b maXX BM1000 Document No 5 07003 04 Baumüller Nürnberg GmbH 100 of 174 8 9 ...
Страница 108: ...Manual b maXX BM1000 Document No 5 07003 04 Baumüller Nürnberg GmbH 108 of 174 ...
Страница 112: ...Recommissioning Manual b maXX BM1000 Document No 5 07003 04 Baumüller Nürnberg GmbH 112 of 174 11 6 ...
Страница 116: ...Recycling plants offices Manual b maXX BM1000 Document No 5 07003 04 Baumüller Nürnberg GmbH 116 of 174 12 4 ...
Страница 118: ...Manual b maXX BM1000 Document No 5 07003 04 Baumüller Nürnberg GmbH 118 of 174 A ...
Страница 140: ...UL certification Manual b maXX BM1000 Document No 5 07003 04 Baumüller Nürnberg GmbH 140 of 174 C 5 ...
Страница 148: ...Fire fighting appliances Manual b maXX BM1000 Document No 5 07003 04 Baumüller Nürnberg GmbH 148 of 174 D 7 ...
Страница 158: ...CANopen display functions Manual b maXX BM1000 Document No 5 07003 04 Baumüller Nürnberg GmbH 158 of 174 E 6 ...
Страница 172: ...Manual b maXX BM1000 Document No 5 07003 04 Baumüller Nürnberg GmbH 172 of 174 Index ...
Страница 174: ...Manual b maXX BM1000 Document No 5 07003 04 Baumüller Nürnberg GmbH 174 of 174 Notes ...
Страница 175: ......