4.3
P0871
This parameter sets the CANopen transmission rate of the b maXX
®
1000.
b maXX
®
1000 CANopen baudrate is set by parameter
only if CANopen hard-
ware address is set to 0 (switch 1 = off, switch 2 = off, switch 3 = off). Otherwise the hard-
ware setting is valid.
P0890
This parameter sets the level of DC braking current output to the motor during start-up
and stopping. When setting DC braking current, the rated current
is regarded
as 100 %. It is recommended to start with a low DC braking current level and then in-
crease until proper holding torque has been achieved. See also
P0891
This parameter determines the duration of the DC braking current after a RUN command.
When the time has elapsed, the b maXX
®
1000 will start accelerating from the minimum
Frequency
P0892
This parameter determines the duration of the DC braking current during stopping. If stop-
ping with DC braking is desired,
stop method must be set to 0 or 2 for ramp to
P0871
CANopen rate
0 to 5
EE
CAN rate
0
STOP
BM_u_CANRate
1:1
-
Value
Meaning
00
1 Mbaud
01
500 kbaud
02
250 kbaud
03
125 kbaud
04
100 kbaud
05
50 kbaud
P0890
DC Bremsstromhöhe
0 to 100 %
EE
DC braking current level
0 %
STOP
BM_u_DCBrakingCurrentLevel
1:1
-
P0891
DC Bremszeit während der Startphase
0.0 to 60.0 s
EE
DC braking time during start-up
0.0 s
STOP
BM_u_DCBrakingDuringStart
10:1
-
P0892
DC Bremszeit während der Stopphase
0.0 to 60.0 s
EE
DC braking time during stopping
0.0 s
STOP
BM_u_DCBrakingDuringStop
10:1
-
Содержание b maXX 1000
Страница 1: ...E 5 07004 03 b maXX 1000 Parameter manual ...
Страница 65: ...Parameter Parameter manual b maXX 1000 Document no 5 07004 03 65 of 208 4 Figure 18 Base block speed search ...
Страница 164: ...Parameter manual b maXX 1000 Document no 5 07004 03 Baumüller Nürnberg GmbH 164 of 208 A ...
Страница 208: ...Parameter manual b maXX 1000 Document no 5 07004 03 Baumüller Nürnberg GmbH 208 of 208 Notes ...
Страница 209: ......