P0893
This parameter determines the frequency when DC braking will begin during decelera-
tion.
Figure 17:
DC braking
DC Braking during start-up is used for loads that may move before the b maXX
®
1000
starts, such as fans and pumps. Under such circumstances, DC braking can be used to
hold the load in position before setting it in motion.
DC Braking during stopping is used to shorten the stopping time and also to hold a
stopped load in position. For high inertia loads, a brake resistor for dynamic braking may
also be needed for fast decelerations.
P0894
This parameter determines the operation mode when the b maXX
®
1000 restarts from a
momentary power loss.
P0893
DC Bremsen Startfrequenz
0.00 to 600.00 Hz
EE
Start point for DC braking
0.00 Hz
STOP
BM_u_StartPointDCBraking
100:1
-
P0894
Antriebsreaktion bei kurzzeitigem Spannungsabfall
0 to 2
EE
Momentary power loss operation selection
0
STOP
BM_u_PowerLossOpSelect
1:1
-
Value
Meaning
0
Operation stops (coast to stop) after momentary power loss.
1
Operation continues after momentary power loss, speed search starts with the master fre-
quency reference value.
2
Operation continues after momentary power loss, speed search starts with the minimum
frequency.
Содержание b maXX 1000
Страница 1: ...E 5 07004 03 b maXX 1000 Parameter manual ...
Страница 65: ...Parameter Parameter manual b maXX 1000 Document no 5 07004 03 65 of 208 4 Figure 18 Base block speed search ...
Страница 164: ...Parameter manual b maXX 1000 Document no 5 07004 03 Baumüller Nürnberg GmbH 164 of 208 A ...
Страница 208: ...Parameter manual b maXX 1000 Document no 5 07004 03 Baumüller Nürnberg GmbH 208 of 208 Notes ...
Страница 209: ......