![Baumuller b maXX 1000 Скачать руководство пользователя страница 24](http://html.mh-extra.com/html/baumuller/b-maxx-1000/b-maxx-1000_parameter-manual_2711401024.webp)
Parameter description
Parameter manual
b maXX
®
1000
Document no. 5.07004.03
Baumüller Nürnberg GmbH
24
4.3
P0036
This parameter sets the mid-point frequency of the V/f curve if
= 0.
With this setting, the V/f ratio between minimum frequency and mid-point frequency can
be determined. This parameter must be equal to or greater than minimum output frequen-
cy
and equal to or less than maximum voltage frequency
. This set-
ting is invalid in vector control mode
= 1.
The settings have to meet the condition of
≤
.
Also see
P0037
This parameter sets the mid-point voltage of any V/f curve if
= 0.
The maximum value depends on the b maXX
®
used, up to 255.0 V for single-phase de-
vices and up to 510.0 V for three-phase devices.
With this setting, the V/f ratio between minimum frequency and mid point frequency can
be determined. This parameter must be equal to or greater than minimum output voltage
and equal to or less than maximum output voltage
. This setting is
invalid in vector control mode
= 1.
The settings have to meet the condition of
≤
≤
.
Also see
P0038
This parameter sets the minimum output frequency of the drive if
= 0.
This parameter must be equal or less than mid-point frequency
. This setting is
invalid in vector control mode
= 1.
The settings have to meet the condition of
≤
≤
.
Also see
P0036
Mittelfrequenz Fmid
0.10 to 600.0 Hz
EE
Mid-point frequency (Fmid)
1.50 Hz
STOP
BM_u_MidPointFreq
100:1 Hz
-
P0037
Mittelspannung Vmid
0.1 to 255.0 V or
0.1 to 510.0 V
EE
Mid-point voltage (Vmid)
10.0 V or 20.0 V
STOP
BM_u_MidPointVolt
10:1 V
-
P0038
Minimale Ausgangsfrequenz Fmin
0.10 to 600.0 Hz
EE
Minimum output frequency (Fmin)
1.50 Hz
STOP
BM_u_MinOutFreq
100:1
-
Содержание b maXX 1000
Страница 1: ...E 5 07004 03 b maXX 1000 Parameter manual ...
Страница 65: ...Parameter Parameter manual b maXX 1000 Document no 5 07004 03 65 of 208 4 Figure 18 Base block speed search ...
Страница 164: ...Parameter manual b maXX 1000 Document no 5 07004 03 Baumüller Nürnberg GmbH 164 of 208 A ...
Страница 208: ...Parameter manual b maXX 1000 Document no 5 07004 03 Baumüller Nürnberg GmbH 208 of 208 Notes ...
Страница 209: ......