Operation in potentially explosive environments
The device complies with the
EU standard 94/9/EG for potentionally explosive atmospheres.
It can be used in accordance with
equipment categories 3 G (explosive gas atmosphere) and
3 D (explosive dust atmosphere).
Equipment category 3 G: - Ex labeling:
II 3G Ex nA T4 X
- Conforms to standard:
(DIN) EN 60079-15: 2004
- Type of protection:
nA
- Temperature class:
T4
- Group of equipment:
II
Equipment category 3 D: - Ex labeling:
II 3D Ex IP65 A22 T135°C X
- Conforms to standard:
(DIN) EN 61241-1: 2004
(DIN) EN 61241-14: 2004
- Protective principle:
Protection by enclosure
- max. surface temperature: +135 °C
- Group of equipment:
II
The operation in other explosive atmospheres is
not permissible.
2.1
In Ex areas the device must only be used within the
ambient temperature range from -20 °C to
+40 °C.
2.2
The plant operator must ensure that any possible
dust deposit does not exceed a thickness of
5 mm, in accordance with (DIN) EN 61241-14: 2004.
2.3
An
UL listing that may be stated elsewhere is not valid for use in explosive environ-
ments.
2.4
Operation of the device is only permissible when ...
the details on the type label of the device match the on-site conditions for the permissible
Ex area in use (group of equipment, equipment category, zone, temperature class or maxi-
mum surface temperature),
the detail on the type label of the device match the electrical supply network,
the device is undamaged (no damage resulting from transport or storage), and
it has been checked that there is no explosive atmosphere, oils, acids, gases, vapors, radi-
ation etc. present during installation.
2.5
It is not permissible to make any alteration to equipment that is used in potentially explosive
environments. Repairs may only be carried out by authorized authorities.
The device must be operated in accordance with the stipulations of the instal-
lation and operating instructions. The relevant laws, regulations and standards
for the planned application must be observed.
–
–
–
–
Operation in potentially explosive environments
2
Содержание HOG 60
Страница 20: ... 17 hog60_mb 07A2 MB76 8 Demontage Dismounting 8 4 Schritt 4 8 4 Step 4 8 3 Schritt 3 8 3 Step 3 ...
Страница 24: ... 21 hog60_mb 07A2 MB76 11 Anhang EU Konformitätserklärung 11 Anhang EU Konformitätserklärung ...
Страница 25: ...MB76 hog60_mb 07A2 22 11 Appendix EU Declaration of conformity Appendix EU Declaration of conformity 11 ...
Страница 26: ...hog60_mb 07A2 MB76 hog60_mb 07A2 MB76 ...
Страница 27: ...MB76 hog60_mb 07A2 ...