ELECTRICAL CONNECTION / PROFIBUS DP
13/29
MB247EN - 11171697, 17A2, Baumer_PMG10-ProfibusDP_II_EN
5.
ELECTRICAL CONNECTION
5.1
Profibus DP
i
Please find a detailed instruction for the Profibus DP interface and the device de
-
scription file in the manual on the CD provided with the device.
5.1.1
Features
Bus protocol
Profibus DP V0* or Profibus DP V2*
Profibus-Features
Profibus DP V0 = Device Class 1 and 2
Profibus DP V2 = Device Class 3 and 4
Data Exch. functions
Input: Position value
Output: Preset value
Preset value
The „Preset“ parameter can be used to set the encoder
to a predefined value that corresponds to a specific axis
position of the system.
Parameter functions
Rotating direction:
The relationship between the rotating direction and
rising or falling output code values can be set in the
operating parameter.
Scaling:
The parameter values set the number of steps per turn
and the overall resolution.
Diagnostic
The encoder supports the following error messages:
- Position error
Default settings
User address 00