![Baumer OM70 Скачать руководство пользователя страница 57](http://html.mh-extra.com/html/baumer/om70/om70_operating-instructions-manual_2710818057.webp)
en_BA_OM70_multi-spot.docx
57/60
Baumer Electric AG
04.01.2021 14:26/tof V1.2 ANW_81156398
Frauenfeld, Switzerland
8
Error correction and tips
8.1
Examples of sensor setup
8.1.1
Simple distance measurement to an object
1.
Connection: In accordance with connection
diagram
2.
Installation: The sensor is installed so the
object is inside the measuring range during
the measuring procedure
3.
Min DIST measurement type for output of
minimum distance to the object
8.1.2
Measurement of the average distance value of a dark object, digital signal at 130 mm distance
1.
Connection: In accordance with connection
diagram
2.
Installation: The sensor is installed so the
object is inside the measuring range during
the measuring procedure.
3.
Avg DIST measurement type for average
value of distance to the object
4.
OBJECT: Set dark
5.
Set switching output DIGITAL OUT to 130
mm as the Point
Object
Measuring range
Measuring
value
Measuring range
Measuring
value
Содержание OM70