![Baumer OM70 Скачать руководство пользователя страница 43](http://html.mh-extra.com/html/baumer/om70/om70_operating-instructions-manual_2710818043.webp)
en_BA_OM70_multi-spot.docx
43/60
Baumer Electric AG
04.01.2021 14:26/tof V1.2 ANW_81156398
Frauenfeld, Switzerland
6.5
Object to be measured
6.5.1
Smallest detectable object
For an object to be reliably detected, it must conform to the minimum object width
1
. This minimum object width
varies with the distance from the sensor.
6.5.2
Reflectivity
Bright objects are generally easier to detect than dark objects, since they are more reflective. Reflectivity is
the percentage relationship between incident and reflected light.
Definition of objects:
White object
Approx. 90% reflectivity
Black object
Approx. 6% reflectivity
Bright object
> 18% reflectivity
Dark object
6…18% reflectivity
6.5.3
Standard object
The technical data for sensors in the data sheet refers to measurements with a Baumer standard object. This
standard object is precisely defined in size, shape and color, making multiple measurements comparable.
Standard object definition:
White ceramic (reflectivity approx. 90%)
Smooth, flat surface
Covers entire sensor measuring range
1
According to data sheet chapter 6.1