5.2 Output responses (output modes)
Signal output response is determined by the following:
-Operating mode selected on DIP-switch 1
-Reset mode selected on DIP-switch 2
-Programming of the preset value, start count value, output time,
output signal logic and output signal function;
-External resetting;
-External counting direction control.
The diagrams below show the output signal responses.
Adding operating mode
External reset with continuous signal
Subtracting operating mode
Automatic reset with pulse signal
External reset with pulse signal
Reset
Preset
Start count
value
Output
Tw
5.3 Counter overrun response
Counter overrun in minus
The minus counting range is 0 to -9999. If -9999 is exceeded, the
range
counter is automatically reset to zero.
Counter overrun in plus
The plus counting range is 0 to 199999. If 100000 is exceeded, prefix
range
zero suppression is cut out and the LED X flashes, indicating the
overrun. If 199999 is exceeded, the counter is automatically reset to
100000.