6
|
Electrical installation
Baumer Hübner
30
Operating Manual
HMG10 & HMG10P DeviceNet | V1, T1
f) Connect cable shield to cable gland and make sure it covers a large area.
g) Attach the cable gland to the terminal box.
h) Mount the terminal box at the encoder. To do this, tighten the screws with a torque of 2-3
Nm.
6.1.3
Pin assignment DeviceNet
1
2
Ill. 5:
Connections HMG10 DeviceNet
1
Mating connector (5-pin, A-coded)
2
Mating connector (5-contact, A-coded)
6.1.3.1
Mating connector (5-pin, A-coded)
1
2
3
4
5
Ill. 6:
Mating connector (5-pin, A-coded)
Pin
Connection
Description
1
DRAIN
Shield connection
2
UB
Operating voltage 10-30 V DC
3
GND
Ground connection for UB
4
CAN_H
CAN Bus Signal (dominant
HIGH)
5
CAN_L
CAN Bus Signal (dominant
LOW)