Villingen-Schwenningen, Germany
Object 6111
Operating parameter Y-axis (Slope long operating parameter) (not with 360° sensor)
SubIndex
0
Data type
Unsigned 8
Access
ReadWrite
Default
0h
EEPROM
Yes
Meaning
Inversion:
Inversion enable means reverse polarity of the Y-axis.
Scaling:
Scaling enable means calculating the slope of the Y-axis as follows:
Slope Y
–axis
= physically measured slope + d
ifferential offset Y- axis
+ o
ffset
Y-axis
When scaling is disabled:
Slope Y
–axis
= physically measured angle
Parameters
Bit 0 = 1 inversion on
0 inversion off
Bit 1 = 1 scaling on
0 scaling off
Object 6112
Preset value Y-axis (Slope long preset value) (not with 360° Sensor)
SubIndex
0
Data type
Integer 32
Access
ReadWrite
Default
0h
EEPROM
Yes
Meaning
Sets the actual slope value Y-axis to the desired value
Parameters
Value range depending on parameters in object 6000h
Objekt 6113
Offset Y-axis (Slope long offset) (not with 360° sensor)
SubIndex
0
Data type
Integer 32
Access
ReadOnly
Default
0h
EEPROM
Yes
Meaning
Calculated offset when writing on object 6112h
Offset Y-axis
=
Preset value Y-axis
at
t
acc
–
physically measured slope
value Y- axis at
t
acc
– d
ifferential offset Y- axis
Parameters
Value range depending on parameters in object 6000h
Objekt 6114
Differential Offset Y-axis (Differential slope long offset) (not with 360° sensor)
SubIndex
0
Data type
Integer 32
Access
ReadWrite
Default
0h
EEPROM
Yes
Meaning
Supplementary offset, independent from objects 6112h and 6113h
The entered value is directly added to the current slope of the Y- axis
Parameters
Value range depending on parameters in object 6000h