This instrument is constructed and tested according to the current EU-
directives and packed in technically safe condition. In order to maintain 
this condition and to ensure safe operation, the user must follow the 
instructions and warnings given in this instruction. 

During the installation local standards have to be observed. Ignoring the 
warnings may lead to severe personal injury or substantial damage to 
property. 

The product must be operated by trained staff. Correct and safe opera-
tion of this equipment is dependent on proper transport, storage, instal-
lation and operation. 

All electrical wiring must conform to local standards and the connection 
must be made according to the connecting diagrams. 

Before switching on the power supply take care that other equipment is 
not affected. Ensure that the supply voltage and the conditions in the 
environment comply with the specification of the device.  

Before switching off the supply voltage check the possible effects on 
other equipment and the processing system. 

To obtain the specified protection degree, the LFFS must be mounted 
with a compliant cable. 

 

Description 

The Level Switch LFFS designed to detect levels in tanks, media separation and provide empty-pipe detection or dry-run protection 
for pumps. 

By means of the FlexProgrammer 9701 the output can be configured to either NPN, PNP or digital output signal. A damping of the 
output signal can be activated in case of a fluctuating media level, e.g. during tank filling. 

The measurement is precise and unaffected by the mounting position in the tank. In the Flex-software a compensation for foam, 
bubbles and condensate as well as viscous media can be set. 

The Flex-software also features an adjustment facility making the user able to adjust the sensor to a specific media.  

The Level Switch LFFS measures liquids such as water and beer as well as viscous, sticky fluids, such as honey, yoghurt, tooth-
paste and ketchup. Even dry medias can be measured, e.g. sugar or flour.  

The Level Switch LFFS is resistant against CIP and SIP agents. 

Hygienic installation is also possible with the comprehensive range of accessories, see the overview at page 6. 

 

WARNING 

When the top cover is removed, do not look directly at the blue LED with unshielded eyes or damage to retina may occur! 
This product contains no replaceable parts. In case of malfunction the product must be shipped to Baumer for repair. 

Operating instructions 
CleverLevel switch, LFFS 

CleverLevel switch, type LFFS is an universal level switch, which 
can be used for all applications in liquids and solids with a DC-
value above 1.5 

Содержание CleverLevel LFFS-1 Series

Страница 1: ...ption The Level Switch LFFS designed to detect levels in tanks media separation and provide empty pipe detection or dry run protection for pumps By means of the FlexProgrammer 9701 the output can be configured to either NPN PNP or digital output signal A damping of the output signal can be activated in case of a fluctuating media level e g during tank filling The measurement is precise and unaffec...

Страница 2: ...Mounting instructions for sliding connection 1 Clean the sliding shaft 2 Mount the smallest ring against the media as indicated 3 Tighten the G1 2 Hygienic sliding nipple at 25 30 Nm 4 Replace the Washer ring kit when one or both parts are permanently deformed or stick to the shaft of the sliding connection The Level Switch LFFS with sliding connection can be mounted in installations with a static...

Страница 3: ...ly Cannot be drained WARNING 5 The 3 A mark or the arrow shall be placed upwards 6 Welding should be grinded to Ra 0 8 7 Tighten the instrument in the adapter with a torque of 15 20 Nm If the seal is leaking and the media appears in the leak detection port the seal is to be changed immediately Before reassembly clean the hole and inside of the connection with detergent and sanitising liquid Use a ...

Страница 4: ... DN 40 ZPH3 3254 for tank tube DN 50 ZPH3 3255 ZPW2 324 Adapter Welding EH FTL to pipe extrusion G A ZPH1 32BA DN 25 DN50 ZPW2 326 G1A ZPH1 32CB DN 65 DN150 ZPW2 327 VS G A ZPH1 32BC G1A ZPH1 32CD Adapter Adapter industrial Adapter industrial G G1 G G1 ZPI1 32B Sliding connection ZPH1 32C0 G G1 ZPI1 32D G G DIN 3852 E G G2 ZPI1 32E ZPI1 32A Welding for tank ZPW2 621 Welding for pipe end ZPW2 626 w...

Страница 5: ...ank with a total in sertion length of 130 mm Hence the external length of the sliding connection will be 250 130 120 mm The media temperature will be max 160 C Read the x axis at 120 mm and the y axis at 160 C and find that the ambient temperature must be kept below 60 C In case the radiated heat from the tank will cause a higher ambient temperature at the housing efficient insulation of the tank ...

Страница 6: ...ight on for 2 seconds Register full state stores the value and returns to Normal operation with new setting NOTE If the media is sticky foamy powdery or in other ways leaving parts of the media at the sensor tip this situation has to be estab lished also during the Teach In process Otherwise a faulty calibration can be the result If Teach In for some reason do not succeed the CleverLevel Switch LF...

Страница 7: ...ed 1 2 5 1 2 5 1 2 5 1 2 5 1 2 5 1 2 5 www baumer com Operating instructions 11109132 09 EN Page 7 20 Active Low NPN and Digital output VDC 2 5V 0 5V Rload 1 kΩ Active High PNP and Digital output VDC 2 5V 0 5V Rload 1 kΩ ATEX Connection type Ambient temperature Media temperature max allowed Note G hygienic 40 85 C 85 C 3A DN38 40 60 C 95 C 1 40 40 C 115 C 1 100 mm 40 85 C 85 C Sliding connection 4...

Страница 8: ... product must be installed in accordance with prevailing guidelines for zone 20 without a barrier Ex data Supply range VDC 12 5 30 Load I 0 1 A Temperature class T1 T5 Pls see table top page 7 12 5 30 1 2 5 ATEX Gas nA A Level Switch LFFS 3xx x is Ex nA II T5 ATEX II 3G approved for application in hazardous areas in accordance with the current EU directives The product must be installed in accorda...

Страница 9: ...net sich hervorragend für die Füllstandserkennung in Behältern die Medientrennung sowie die Erkennung leerer Rohre und den Trockenlaufschutz von Pumpen Mithilfe des FlexProgrammer 9701 kann der Ausgang als NPN PNP oder ein digitales Ausgangssignal konfiguriert werden Im Falle eines veränderlichen Medienfüllstandes z B während der Befüllung des Behälters kann eine Dämpfung des Ausgangssig nals akti...

Страница 10: ...werden Bitte keine Dichtungen aus PTFE Fasern oder sonstige Dich tungen verwenden Wenn sich die aus PEEK bestehende Spit ze gegen die Einschweissmuffe aus Edelstahl drückt bildet dies eine hygienegerechte Dichtung vorausgesetzt die Richtli nien wurden befolgt Aufgrund des Messprinzips ist es wichtig dass für die Sensor spitze ein ausreichend grosses Stück von Metallachse oder Einschweissmuffe sich...

Страница 11: ...3A Markierung bzw der Pfeil sollte nach oben zeigen 6 Schweissnähte sollten so abgeschliffen werden dass sie einen Wert von Ra 0 8 aufweisen 7 Gerät im Adapter mit einem Drehmoment von 15 20 Nm festzie hen Wenn die Dichtung undicht ist und die Medien in der Kontrollbohrung sichtbar werden muss die Dichtung sofort ausgetauscht werden Vor dem erneuten Zusammenbau die Bohrung und das Innere des Ansch...

Страница 12: ...254 für Behälter Rohr DN 50 ZPH3 3255 ZPW2 324 Adapter Einschweissmuffe EH FTL für Rohr mit Auszug G A ZPH1 32BA DN 25 DN50 ZPW2 326 G1A ZPH1 32CB DN 65 DN150 ZPW2 327 VS G A ZPH1 32BC G1A ZPH1 32CD Adapter Adapter Industriell Adapter Industriell G G1 G G1 ZPI1 32B verschiebbarer Anschl ZPH1 32C0 G G1 ZPI1 32D G G DIN 3852 E G G2 ZPI1 32E ZPI1 32A Einschweissmuffe für Behälter ZPW2 621 Einschweiss...

Страница 13: ...von 130 mm in einen Tank montiert Seine externe Länge beträgt daher 250 130 120 mm Die Medientemperatur beträgt max 160 C Liest man den Schnittpunkt aus 120 mm auf der X Achse und 160 C auf der Y Achse ab so ergibt sich dass die Umgebungs temperatur unter 60 C gehalten werden muss Falls die Abstrahlwärme vom Behälter zu einer höheren Umgebungs temperatur am Gehäuse führt muss für eine wirksame Iso...

Страница 14: ...rz an VDC anschliessen Leuchtet 2 Sekunden lang Registriert den Zustand gefüllt speichert den Wert und kehrt mit den neuen Einstellungen zum Normalbetrieb zurück ANMERKUNG Bei klebrigen schäumenden pulvrigen oder anderen Medien von denen leicht Reste an der Sensorspitze haften bleiben müssen diese Bedingungen auch während des Teach In Verfahrens vorliegen Andernfalls kann die Kalibrierung fehlerha...

Страница 15: ... Schliesser NO Öffner NC Elektrische Daten Spannungsversorgung 12 5 36 VDC 35 mA max Ausgang PNP NPN oder Digital Max 50 mA kurzschlussfest und hochtemperaturfest Low aktiv NPN und digitaler Ausgang VDC 2 5V 0 5V Rload 1 kΩ High aktiv PNP und digitaler Ausgang VDC 2 5V 0 5V Rload 1 kΩ 1 2 5 1 2 5 1 2 5 1 2 5 1 2 5 1 2 5 www baumer com Betriebsanleitung 11109132 09 DE Page 15 20 PNP Ausgang NPN Aus...

Страница 16: ...C 1 100 mm 40 85 C 85 C verschiebbarer Anschluss 40 60 C 155 C 1 40 40 C 175 C 1 250 mm 40 85 C 85 C verschiebbarer Anschluss 40 60 C 195 C 1 40 40 C 200 C 1 Bedingungen für Ex Zertifizierung 1 Gilt unter der Voraussetzung dass die Sensor spitze am Gerät als einziges Teil mit dem Medium in Berührung ist ATEX Gas ia LFFS 1xx x mit PNP Ausgang Safe area 22 120 VDC or 90 253 VAC ANMERKUNG Bei PNP Aus...

Страница 17: ...Produkt ist gemäss den üblichen Richtli nien für Zone 2 ohne Barriere zu installieren Ex Daten Spannungsversorgung VDC 12 5 30 Last I 0 1 A Temperaturklasse T1 T5 Siehe Tabelle oben auf Seite 16 Der FlexProgrammer 9701 darf in der gefährlichen Umgebung nicht an den Füll standsschalter LFFS angeschlossen werden Vorgehensweise bei der Konfigurierung a Netz vom 4 20 mA Regelkreis trennen b Füllstands...

Страница 18: ...WHG leakage and overfill protection approval Betriebsanleitung CleverLevel switch LFFS www baumer com Betriebsanleitung 11109132 09 DE Page 18 20 ...

Страница 19: ...Betriebsanleitung CleverLevel switch LFFS www baumer com Betriebsanleitung 11109132 09 DE Page 19 20 WHG leakage and overfill protection approval ...

Страница 20: ...www baumer com Betriebsanleitung 11109132 09 DE Page 20 20 For further information please refer to www baumer com ...

Отзывы: