24
o
When fitting a new tap, ensure that a new gasket is used.
o
Reconnect the gas tap, perform a gas soundness test and
then reassemble the hob.
Electrical connection
This appliance must be installed by a qualified
person in accordance with the latest edition of the
I.E.E. Regulations and in compliance with the
manufacturer’s instructions.
Before connecting the appliance, make sure that the supply voltage
marked on the rating plate corresponds with your mains supply
voltage.
o
Cable type: H05 RRF 3 core x 0.75 mm³ (Type RR-F <HAR>
marked).
o
The mains supply cable is supplied with this product.
Replacing the mains supply cable
If the mains supply cable is damaged, then it must be replaced by an
appropriate replacement which can be obtained from the Spares
Department.
The mains supply cable should be replaced in accordance with the
following instructions:
o
Switch the appliance off at your mains supply.
o
Open the box of the supply board.
o
Unscrew the clamp fixing the cable.
o
Replace the cable with one of the same length and in accordance
with the specification given above.
o
The “green-yellow” earth wire must be connected to the terminal
marked
. It must be about 10 mm longer than the live and
neutral wires.
o
The “blue” neutral wire must be connected to the terminal
marked with the letter (N).
o
The “brown” live wire must be connected to the terminal marked
with the letter (L).
Содержание HHG610SS