OK
NO
Fig. 10B
Fig. 10
GB
WARNINGS
The technical data are indicated on the data nameplate placed
on the rear of the appliance.
The adjustment conditions are stated on the label applied on the
packaging and on the appliance.
Do not use the oven door handle to move the appliance, such as
to remove it from the packaging.
INSTRUCTIONS DESTINED TO THE USER
OVERALL DIMENSIONS
X
600
610
B
725
60
The cooker is fitted with 4 legs (fig.10).
Adjustable height only for some models.
*
GAS APPLIANCES
This appliance is not connected to a device to vent the combustion
products. It must therefore be installed and connected in conformity
with the installation standards in force.
Particular attention must be paid to the standards on ventilation
of the room.
VENTILATION OF ROOMS
Remember that this appliance can be installed and work in well-
ventilated rooms only, according to the standards in force, such
as to allow, with openings on the external walls or with special
ducts, a correct natural or forced ventilation
ensuring permanently
and sufficiently
both the entry of the air needed for correct
combustion and the removal of spent air.
In particular when there is only this gas appliance in the room,
there must be a hood over the appliance to ensure the natural
and direct removal of spent air, with a vertical straight duct of
length equal to at least twice the diameter and a minimum section
of at least 100 cm2.
For the indispensable entry of fresh air into the room there must
be a similar 100 cm2 opening directly to the outside, situated at
a height near floor level so that it is not blocked either inside or
outside the wall and so as not to cause disturbances to correct
burners combustion and to the regular removal of spent air and
with a difference of height with respect to the outlet opening of at
least 180 cm.
Remember that the quantity of air necessary for combustion must
never be less than 2m3/h for each kW of power (see total power
in kW on the appliance data plate fig. 10B ).
In all other cases, i.e. when there are other gas appliances in the
same room, or when natural direct ventilation is not possible and
natural indirect or forced ventilation must be installed, contact a
qualified specialist who will install and make the ventilation system,
scrupulously observing the regulations contained in the standards
in force.
The openings must be so positioned that there are no draughts
of air which cannot be tolerated by the occupants.
Moreover to eliminate combustion products, it is forbidden to use
flues already used by other appliances.
INSTALLATION
IMPORTANT:
The coating of the furniture must be able to withstand
high temperatures (min. 90°C).
If the appliance is to be installed near units, leave the minimum
gaps specified in the table below.
B = reg. 95 / 130 mm (according to the models).
A = 30 mm (according to the models).
A
B = 95 mm
A = 40 mm (according to the models).
A = 25 mm (according to the models).
min. 20mm
min.100 mm
min. 50 mm
min. 50 mm
min.
650 mm
min.
400 mm
min. 20mm
X
(mod. 296) = 895 mm
X
(mod. 206) = 1000 mm
8
min.
180 cm.
min. 100cm
2
.
min.
180 cm.
electrical fan
min. 100cm
2
.
min. 100cm
2
.
h* = Adjustment
max 15 mm
600
900
960
1000
h*
Содержание BMEC9GGESS
Страница 5: ......
Страница 23: ...A A V A A A T H Z 10...
Страница 24: ...537961 Libretto cuc 296 F GAS Page 1 29 12 2008 11 54 02...
Страница 25: ...OK NO F min 100cm2 F A A 8 F F A A A...
Страница 26: ...537961 Libretto cuc 296 F GAS Page 1 29 12 2008 12 10 56 600...
Страница 27: ...H05 RR F H05 RR F 2 1 3 4 5 L N A N 6 A A...
Страница 29: ...537961 Libretto cuc 296 F GAS Page 1 29 12 2008 17 09 50...
Страница 30: ...537961 Libretto cuc 296 F GAS Page 1 29 12 2008 17 14 45...
Страница 32: ......