14
Operating Manual for
BAUER Separator S300
S
5.1 SETUP AND OPERATION OF THE MOTOR
The motors in the standard design are suitable for operation up to a maximum ambient temperature of
+40 °C (104 °F) as well as an elevation of up to 1000 m above sea level.
Conditions of high humidity (e.g. locations near to the coast) and extreme sunlight require special designs
for the gears and motors. Consult the manufacturer concerning such designs.
The motors must be set up to allow unimpeded inflow of fresh air and dispersal of warm air. Removal of
the fan blade and the fan housing or enclosing the motor in a housing are prohibited since the supply of
cooling air would be reduced in both cases. This would cause the motor to overheat.
DANGER
Before making changes or inspecting the motor or switch cabinet, the machine must
be disconnected on all sides and all poles and secured against reactivation!
Always keep the switch cabinet closed!
DANGER
It must be noted that a pressed EMERGENCY OFF button does not provide any pro-
tection against unauthorized starting of the machine.
5.2 CONDENSATE HOLE
We recommend a condensate hole on motors that are subjected to high temperature fluctuations or ex-
treme climatic conditions.
DANGER
A motor protection circuit breaker or a protection device with overload relay must always be
installed to protect the motor winding. Fuses do not protect the motor from overloads; they
only protect the electrical supply lines or switching systems from damage in event of a
short-circuit.
5.3 INSTALLATION WITHOUT SWITCH CABINET
If the BAUER separator was delivered or ordered without a switch cabinet, a few basic rules must
be followed in controlling the separator; otherwise, the warranty is void:
The motor must be equipped with electrical protection to prevent impermissible current loads ex-
ceeding the rated current on the type plate.
Operating the separator without an inflow of material must be prevented by means of electrical
control since dry running would otherwise result in increased wear on the screen and auger, which
would significantly reduce their service lives. For this reason, the separator should be started up
along with the start of the medium supply and stopped between 30 and 60 seconds after the me-
dium supply is stopped.
Содержание S300
Страница 1: ...ORIGINAL OPERATING MANUAL FOR SEPARATOR S300 Version II 2019 ...
Страница 2: ......