background image

 
 
 
 

Shanghai Baudcom Communication Device Co.,Ltd 

Website:    www.baudcom.com.cn                      Tel: +86 21 37709251                    Email: [email protected]

 

 

 

                                                                                               

                                     

 

 
 

                         

 

 
 

 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 

Version 1.00 

 
 

 
 

Warning: Ignore the warning, non-proper use of fusion splicer could lead to fatal 

and serious inju

r

y

.

 

 

1. The input voltage of this model of machine is definite; please do not use the voltage 

outside the scope. Please use the correct AC and DC power supply. 

2.  When  the  fusion  splicer  comes  across  the  following  failures,  please  immediately 

remove  the  AC  power  cord  from  the  power  supply  input  and  turn  off  the  fusion 

splicer,  otherwise  will  lead  to  the  incapable  of  the  repairing  and  even  will  cause 

personal injury, death and fire.

 

    BD-FS-30

 

Optical Fiber Fusion Splicer 

 

User Manual

 

Содержание BD-FS-30

Страница 1: ...f this model of machine is definite please do not use the voltage outside the scope Please use the correct AC and DC power supply 2 When the fusion splicer comes across the following failures please i...

Страница 2: ...ake in maintenance will lead to the machine beyond repair even causing bodily harm 4 The machine has strictly limitation to the power supply module used 5 The fusion splicer is prohibited to be used u...

Страница 3: ...4 2 3 Battery supply operation 5 2 4 Turn on and turn off 8 2 5 Display brightness control 9 2 6 Cover fiber protection sleeve 9 2 7 Preparation of fiber end face 10 2 8 Place fiber 11 3 Check and Ma...

Страница 4: ...25mm 0 9mm fiber SC connector option Splicing Time 9s Heat Time 30s Cleaved Length 8 16mm Fiber Image Magnification 350 280 View Display 5 inch digital high quality LCD screen Tension Test Standard 2N...

Страница 5: ...cn 1 Fusion Splicer 1 set 2 Carrying Case 1 set 3 AC Adaptor 1 pc 4 Power cord 1 pc 5 Cooling tray 1 pc 6 Spare Electrodes 1 pair 7 User Manual CD 1 pc 8 Test Report 1 pc 1 3 Parts Name of fusion spl...

Страница 6: ...isplay The optical fiber moves downward Invalid Increase the parameter quantum or move the cursor Invalid The optical fiber moves left Invalid Increase the parameter quantum or move the cursor Turn on...

Страница 7: ...le for field work Operation is simple fusion speed is high and fusion loss is small 2 1 Descriptions of the power modules The Fusion Splicer uses 2 in 1 power module design during the work the Fusion...

Страница 8: ...rranged in the battery case the battery pack will also be charged when the adapter is supplying power However it is recommended that the Fusion Splicer be shut when charged 2 3 Battery supply operatio...

Страница 9: ...arging indicator CHARGE light is red after the charging completion the charging indicator CHARGE will be green 3 When the splicer is shut down the maximum charging time is three hours 40 minutes and t...

Страница 10: ...life belongs to consumables When the fusion splicer can only work for a short time despite the battery level of the lithium battery above 90 please replace the battery Please use the battery of the m...

Страница 11: ...s stored for a long time it should be charged with the special charger provided by the Company once every 90 days The life of the battery may be extended if the battery is half fully charged in a long...

Страница 12: ...he Fusion Splicer operation Display brightness control should be done in the standby operation interface 1 Press or in the standby operation interface to change the brightness of the display 2 Press t...

Страница 13: ...l or wadding soft enough to wipe clean the fiber Wiping with a clean cotton cloth once and do not clean it with the same cloth for the second time Notes Please use the alcohol with purity more than 99...

Страница 14: ...n fixed containers 2 7 6 Pinch and hold the fiber with the left hand and open the small clip with the right hand at the same time and carefully remove the fiber Notes The clean cross section of fiber...

Страница 15: ...ce don t touch the V shape groove when place the fiber 2 8 4 Place another optical fiber according to the above steps 2 8 5 Close shielding cover 3 Check and Maintenance Critical cleaning points and m...

Страница 16: ...r quality splices The fiber clamp chips should be frequently inspected and periodically cleaned during normal operation 2 To clean the clamp chips do the following Open the wind protector Clean the su...

Страница 17: ...objective lenses always turn off the splicer Do not hit or touch tip of electrode when cleaning it 2 Gently clean the surface of lenses X axis and Y axis with an alcohol impregnated thin cotton swab...

Страница 18: ...ning on the power Using the electrodes without a replacement will result in greater splice loss and reduced splice strength Replace Electrodes 1 Press button on the operator panel until the LED indica...

Страница 19: ...ursor to select the Calendar 2 Press to enter Current Calendar interface Move the cursor to select the item to be changed Press to adjust the value 3 After completion of calendar setting press The dat...

Страница 20: ...Aligning the card slot place new battery into the power module and make sure it is plugged in tightly then close the cover of the battery case which is at the bottom of the Fusion Splicer 5 Power Sup...

Страница 21: ...onsumption The AC DC adapter is not the model supplied by the Company or the charging time is not long enough CHARGE LED on AC adapter blinks during battery recharge Atmospheric temperature is too hig...

Страница 22: ...nd pressure and the long service of the machine creates variability in the arc temperature and position Step of discharge calibration In the Ready mode press to enter Splice Menu menu Then prepare and...

Страница 23: ...finished fiber in the Fusion Splicer Cross section of fiber can not touch other things Cover the wind protector then the fiber fusion automatically starts and the splicing loss is displayed Reinforce...

Страница 24: ...ies and accessories or other external factors such as voltage instability Unauthorized disassemble or repair Consumable parts such as electrode cleaver blade carrying case of fusion splicer etc Before...

Страница 25: ...Website www baudcom com cn Tel 86 21 37709251 Email info baudcom com cn Addenda C Contact Notice This Company s products are ameliorated continually modification won t be informed...

Отзывы: