lock the keyboard to disable input. The user should press
until the
Fusion Splicer is shut down, and charge the lithium battery pack as soon as
possible, or use the adapter to supply power.
2.3.4 The other considerations
<1> For any fusion splicer not to be used for more than 1 month, it is
suggested to separate the lithium battery and machine for saving.
<2>
The lithium battery should be charged in the environmental
temperature ranging between 0
℃~+
40
℃
.
<3> The battery, with certain service life, belongs to consumables. When
the fusion splicer can only work for a short time despite the battery
level of the lithium battery above 90%, please replace the battery.
Please use the battery of the model designated by the Company for
replacement.
<4> Before the battery power supply for the fusion splicer, the battery
level must be checked. If the battery is low or the low voltage
warning is given, please recharge the lithium battery timely.
<5> Please do not charge or discharge the battery in a low temperature for
a long time to prevent the decrease of the battery life. Accidents may
happen if charging or discharging the battery or special battery charger
and battery in a high temperature.
<6>When charging the battery with the special battery charger,